(CTRL + F) for fast search.

Ingecon SUN 30TL M3-50TL M4 Manual

INGECON® SUN 30TL M3 / 50TL M4

Overview

The INGECON® SUN 30TL M3 and 50TL M4 are three-phase PV inverters designed for commercial and industrial self-consumption systems. These inverters feature three or four independent Maximum Power Point Trackers (MPPT), ensuring optimal energy harnessing from the PV array, even under challenging conditions such as scattered clouds and partial shading.

Key Features

  • Maximum Efficiency: 98.2% with multiple independent MPPT inputs.
  • Plug & Play Technology: Easy and fast installation with country-specific configuration via App.
  • Rugged Design: Die cast aluminum casing for indoor and outdoor applications (IP66).
  • Ease of Maintenance: Internal datalogger, remote and on-site control, and LED status indicators.
  • Software Included: INGECON® SUN Monitor and iSun Monitor for monitoring and recording inverter data over the internet.
  • Communications: Ethernet and Wi-Fi as standard.
  • Warranty: Standard 5-year warranty, extendable up to 25 years.

Main Features

  • EMS inside.
  • Multi-MPPT system.
  • 98.2% maximum efficiency.
  • Digital inputs.
  • Ethernet and Wi-Fi communications supplied as standard.
  • Remote configuration and upgrade.
  • Software INGECON® SUN Monitor for PV plant monitoring.
  • LED Status.
  • Easy maintenance.
  • Plug & Play technology.
  • Suitable for indoor and outdoor installations (IP66).
  • High temperature performance.
  • Compact design.
  • Configurable language, rated voltage, and country code via App.
  • Compatible with high power modules (500W-600W+).

Protections

  • Reverse polarity protection.
  • Short circuits and overloads at the output.
  • Anti-islanding with automatic disconnection.
  • Insulation faults.
  • Input and output overvoltages with type II surge arresters.
  • DC Fuses.

Optional Accessories

  • Self-consumption kit.

Benefits

  • Greater performance thanks to the multi MPPT system.
  • Easy maintenance.
  • Higher inverter life expectancy.
  • Waterproof and dustproof (IP66).
  • Anti-corrosion with C5 protection class.

All models feature DC and AC surge arresters type II, DC fuses, input current measuring kit, and an integrated DC switch.

Technical Specifications

Specification 30TL M3 50TL M4
Input (DC)
Recommended PV array power range 30.9 - 45 kWp 51.5 - 75 kWp
Voltage range MPPT 180 - 1,000 V 180 - 1,000 V
Start input voltage 250 V 250 V
Maximum voltage 1,100 V 1,100 V
Rated input voltage 620 V 620 V
Max. Short circuit current 50 A + 2*45 A 50 A + 3*45 A
Maximum current 40 A + 2*32 A 40 A + 3*32 A
Inputs with PV connectors 6 (2/2/2) 8 (2/2/2/2)
Number of MPPTs 3 4
Output (AC)
Rated power 30 kW 50 kW
Max. apparent power (1) 33 kVA 55 kVA
Max. active power (PF = 1) (1) 33 kW 55 kW
Max. output current 51 A 84.3 A
Rated voltage 400 V 400 V
Voltage range (2) 322 - 520 V (Adjustable) 322 - 520 V (Adjustable)
Frequency 50 / 60 Hz 50 / 60 Hz
Type of grid TT / TN TT / TN
Power Factor adjustable Yes, 0 - 1 (leading / lagging) Yes, 0 - 1 (leading / lagging)
Efficiency
Maximum efficiency 98.2% 98.2%
Euroefficiency 97.8% 97.8%
General Information
Refrigeration system Natural cooling Forced ventilation
Consumption at night < 15 W < 15 W
Ambient temperature -25°C to 60°C -25°C to 60°C
Relative humidity (non-condensing) 0 - 100% 0 - 100%
Protection class IP66 IP66
Marking CE CE
Acoustic emissions < 35 dB < 50 dB
Max. Operating altitude 4,000 m 4,000 m
EMC and security standards EN 61000-6-2, EN 61000-6-4, EN 61000-3-3, EN 61000-3-12, EN 62109-1, EN 62109-2 EN 61000-6-2, EN 61000-6-4, EN 61000-3-3, EN 61000-3-12, EN 62109-1, EN 62109-2
Grid connection standards IEC 61727; IEC 62116; EN 50549-1; IEC 61727:2004; IEC 62116:2014; EN 50549-1:2019; EN 50549-2:2019;UNE 217002:2020 RD647; NTS SEPE 2.1 type A & A; CEI 0-21 V1 November 2022; CEI 0-16 V1 November 2022; VDE-AR-N 4105 IEC 61727; IEC 62116; EN 50549-1; IEC 61727:2004; IEC 62116:2014; EN 50549-1:2019; EN 50549-2:2019;UNE 217002:2020 RD647; NTS SEPE 2.1 type A & A; CEI 0-21 V1 November 2022; CEI 0-16 V1 November 2022; VDE-AR-N 4105
Integrated Elements
DC switch Yes Yes
Anti-islanding protection Yes Yes
AC overcurrent protection Yes Yes
AC short-circuit protection Yes Yes
DC reverse connection Yes Yes
DC & AC surge arresters, type III Yes Yes
Insulation detection Yes Yes
Leakage current protection Yes Yes
PV string monitoring Yes Yes

Dimensions and Weight

  • 30TL M3:

    • Dimensions: 635 x 530 x 224 mm
    • Weight: 32 kg
  • 50TL M4:

    • Dimensions: 635 x 530 x 224 mm
    • Weight: 43 kg

Notes

  • In Spain, the maximum active power will be the same as the rated power.
  • The range of output voltage and frequency may vary depending upon different grid codes.