Solar Inverter
KS 5 Series (3–5kW)
Overview
EFFEKTA KS 5 series solar inverters convert DC current from solar modules into AC current and feed it into the power grid. They feature a DC/DC converter with a maximum power point tracker (MPPT) on the input side and a single-phase inverter on the output side, synchronized with the grid. These inverters are available in models with either 1 MPP tracker (ST) or 2 MPP trackers (DT) and are ideal for private use.
Special Features
- Outstanding efficiency (up to 98.3%)
- Lightweight and compact design
- Extended input voltage range up to 600 VDC
- Simple operation with 4 buttons and LCD display
- SOLARMAN app connection for easy operation, monitoring, and yield evaluation
- Optional features: WLAN-Plug, external DC disconnect switch, external current sensor
Characteristics
- Euro efficiency up to 97.9%
- High MPPT accuracy
- Low night power loss
- Perfect cooling concept without fans
- Easy installation
Specifications
Models: KS 5 3000ST, KS 5 5000DT
Input (DC)
-
Nominal DC power: 3000 W (3000ST), 6000 W (5000DT)
-
Max. DC voltage: 600 VDC
-
Max. input current per tracker: 15 A
-
Number of MPP trackers: 1 (3000ST), 2 (5000DT)
-
MPPT voltage range: 80 - 560 VDC
Output (AC)
-
Nominal AC power: 3000 W (3000ST), 4600 W (5000DT)
-
Max. AC power: 3300 W (3000ST), 4600 W (5000DT)
-
Max. output current: 14.5 A (3000ST), 20 A (5000DT)
-
AC voltage: 1 / N / PE, 230 VAC
-
AC voltage window: 184 VAC – 262 VAC (Base 230 VAC)
-
Frequency: 50 Hz, auto detect
-
Power factor: 1
-
Total harmonic distortion (THDi): < 3%
Efficiency
-
Max. efficiency: 98.1% (3000ST), 98.3% (5000DT)
-
Euro-efficiency: 97.7% (3000ST), 97.9% (5000DT)
General/Mechanical Data
-
Dimensions (H x W x D): 380 x 380 x 150 mm
-
Weight: 10 kg (3000ST), 11 kg (5000DT)
-
Operating temperature range: -25°C to +60°C
-
Ingress protection: IP65 (not intended for outdoor use)
-
Cooling concept: Convection cooling
-
LCD Display: Yes
-
Communication Interface: RS485/external Wi-Fi (optional)
-
Compatibility: SOLARMAN (yes), Solar-LogTM (no)
Terminals
-
Input (AC): Terminal connections
-
Output (DC): MC-4
Protection
-
Utility grid: Over/under voltage, over/under frequency, ground fault monitoring, DC isolation fault
-
Short circuit: DC input: reverse polarity protection/electronic circuit; AC output: output relay/electronic circuit
Regulations/Standards
-
Safety: IEC 62109-1:2010, EN 62109-1:2010, IEC 62109-1:2011, EN 62109-2:2011, VDE V 0126-1-1:2013, VDE-AR-N 4105:2018, VDE V 0124-100:2020
-
EMC: EN 61000-6-1:2019, EN 61000-6-3:2007+A1:2011
-
Certifications: CE
Note: Power reduction in the corresponding country specification "Germany" according to VDE-AR-N-4105. Exceeding or outside of MPPT voltage range will result in an error message and no power feeding.