The PVS-100/120-TL is a cloud-connected, three-phase string inverter designed by FIMER for cost-efficient, decentralized photovoltaic (PV) systems. It is suitable for both ground-mounted and large commercial applications.
Key Features
-
Power Rating: 100 kW for 400 Vac and 120 kW for 480 Vac
-
MPPTs: Up to 6 independent Maximum Power Point Trackers (MPPT)
-
Efficiency: Maximum efficiency up to 98.9%
-
Installation: Supports both vertical and horizontal mounting
-
Connectivity: Wi-Fi standard for configuration, two Ethernet ports
-
Communication: Modbus RTU/TCP (Sunspec compliant)
-
Environmental Protection: IP66 for the main body, IP54 for the cooling section
Technical Specifications
Input Side
-
Max DC Input Voltage: 1000 V
-
Start-up DC Input Voltage: 420 V (400-500 V)
-
Operating DC Input Voltage Range: 360-1000 V
-
Rated DC Input Voltage:
- PVS-100-TL: 620 V
- PVS-120-TL: 720 V
-
Rated DC Input Power:
- PVS-100-TL: 102000 W
- PVS-120-TL: 123000 W
-
MPPT Input Voltage Range:
- PVS-100-TL: 480-850 V (symmetrical load)
- PVS-120-TL: 570-850 V (symmetrical load)
-
Max DC Input Power per MPPT:
- PVS-100-TL: 21000 W or 63000 W (depending on MPPT configuration)
- PVS-120-TL: 25000 W or 75000 W (depending on MPPT configuration)
-
Max DC Input Current per MPPT:
- PVS-100-TL: 36 A or 108 A
- PVS-120-TL: 36 A or 108 A
-
Max Input Short Circuit Current per MPPT: 50 A or 150 A
-
DC Connection Type: PV quick fit connector, various cable glands
Output Side
-
Grid Connection Type: Three-phase 3W+PE or 4W+PE
-
Rated AC Power:
- PVS-100-TL: 100000 W
- PVS-120-TL: 120000 W
-
Max AC Output Power:
- PVS-100-TL: 100000 W
- PVS-120-TL: 120000 W
-
Rated AC Grid Voltage:
- PVS-100-TL: 400 V
- PVS-120-TL: 480 V
-
AC Voltage Range:
- PVS-100-TL: 320-480 V
- PVS-120-TL: 384-576 V
-
Max AC Output Current: 145 A
-
Rated Output Frequency: 50 Hz / 60 Hz
-
Output Frequency Range: 45-55 Hz / 55-65 Hz
-
Nominal Power Factor: > 0.995, adjustable range 0-1 inductive/capacitive
-
Total Current Harmonic Distortion: < 3%
-
Max DC Current Injection: < 0.5%*In
Protection and Monitoring
-
Input Protection: Reverse polarity protection, over-voltage protection, isolation control, residual current monitoring, DC switch rating, and fuse rating.
-
Output Protection: Anti-islanding protection, external AC overcurrent protection, output overvoltage protection with replaceable surge protection device (Type 2).
Environmental and Physical
-
Operating Temperature Range: -25 to +60°C (-13 to 140°F) with derating above 40°C (104°F)
-
Relative Humidity: 4% to 100% condensing
-
Sound Pressure Level: Typical 68 dB(A) at 1 meter
-
Max Operating Altitude: 2000 meters (6560 feet)
-
Cooling: Forced air
-
Dimensions: 869 x 1086 x 419 mm (34.2” x 42.7” x 16.5”)
-
Weight: 70 kg (154 lbs) for power module; ~55 kg (121 lbs) for wiring box; overall max 125 kg (276 lbs)
-
Mounting System: Mounting bracket for vertical and horizontal support
Communication and Interface
-
Embedded Communication Interfaces: 1x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2.4 GHz)
-
User Interface: 4 LEDs, Web User Interface
-
Communication Protocol: Modbus RTU/TCP (Sunspec compliant)
-
Commissioning Tool: Web User Interface, Mobile APP/APP for plant level
-
Remote Monitoring Services: Aurora Vision monitoring portal
-
Advanced Features: Embedded logging, direct telemetry data transferring to ABB cloud
Available Product Variants
-
Inverter Power Module: PVS-100-TL-POWER MODULE / PVS-120-TL-POWER MODULE
-
Wiring Box Versions:
- SX2: Individual string monitoring, positive pole fuses, DC disconnect switches, surge arresters
- SX: Individual string monitoring, both positive and negative pole fuses, DC disconnect switches, surge arresters
- SY2: MPPT level input current monitoring, positive pole fuses, DC disconnect switches, surge arresters
- SY: MPPT level input current monitoring, both positive and negative pole fuses, DC disconnect switches, surge arresters
- S2: MPPT level input current monitoring, cable gland input, DC disconnect switches, surge arresters
Optional Accessories
-
AC Plate for Single Core Cables: Various individual AC cable glands
-
AC Plate for Multi Core Cables: Various individual AC cable glands
-
Pre-Charge Board Kit: Night time operation with restart capability
-
Grounding Kit: Allows connection of the negative input pole to the ground
Compliance and Standards
-
Safety and EMC Standards: IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-4
-
Grid Standards: Various international standards including CEI 0-16, IEC 61727, IEC 62116, etc.