(CTRL + F) hızlı arama için.

PVS-100/120-TL Manual

Solar Inverter: PVS-100/120-TL Overview

General Description

The PVS-100/120-TL is a cloud-connected, three-phase string inverter designed by FIMER for cost-efficient, decentralized photovoltaic (PV) systems. It is suitable for both ground-mounted and large commercial applications.

Key Features

  • Power Rating: 100 kW for 400 Vac and 120 kW for 480 Vac
  • MPPTs: Up to 6 independent Maximum Power Point Trackers (MPPT)
  • Efficiency: Maximum efficiency up to 98.9%
  • Installation: Supports both vertical and horizontal mounting
  • Connectivity: Wi-Fi standard for configuration, two Ethernet ports
  • Communication: Modbus RTU/TCP (Sunspec compliant)
  • Environmental Protection: IP66 for the main body, IP54 for the cooling section

Technical Specifications

Input Side

  • Max DC Input Voltage: 1000 V
  • Start-up DC Input Voltage: 420 V (400-500 V)
  • Operating DC Input Voltage Range: 360-1000 V
  • Rated DC Input Voltage:
    • PVS-100-TL: 620 V
    • PVS-120-TL: 720 V
  • Rated DC Input Power:
    • PVS-100-TL: 102000 W
    • PVS-120-TL: 123000 W
  • MPPT Input Voltage Range:
    • PVS-100-TL: 480-850 V (symmetrical load)
    • PVS-120-TL: 570-850 V (symmetrical load)
  • Max DC Input Power per MPPT:
    • PVS-100-TL: 21000 W or 63000 W (depending on MPPT configuration)
    • PVS-120-TL: 25000 W or 75000 W (depending on MPPT configuration)
  • Max DC Input Current per MPPT:
    • PVS-100-TL: 36 A or 108 A
    • PVS-120-TL: 36 A or 108 A
  • Max Input Short Circuit Current per MPPT: 50 A or 150 A
  • DC Connection Type: PV quick fit connector, various cable glands

Output Side

  • Grid Connection Type: Three-phase 3W+PE or 4W+PE
  • Rated AC Power:
    • PVS-100-TL: 100000 W
    • PVS-120-TL: 120000 W
  • Max AC Output Power:
    • PVS-100-TL: 100000 W
    • PVS-120-TL: 120000 W
  • Rated AC Grid Voltage:
    • PVS-100-TL: 400 V
    • PVS-120-TL: 480 V
  • AC Voltage Range:
    • PVS-100-TL: 320-480 V
    • PVS-120-TL: 384-576 V
  • Max AC Output Current: 145 A
  • Rated Output Frequency: 50 Hz / 60 Hz
  • Output Frequency Range: 45-55 Hz / 55-65 Hz
  • Nominal Power Factor: > 0.995, adjustable range 0-1 inductive/capacitive
  • Total Current Harmonic Distortion: < 3%
  • Max DC Current Injection: < 0.5%*In

Protection and Monitoring

  • Input Protection: Reverse polarity protection, over-voltage protection, isolation control, residual current monitoring, DC switch rating, and fuse rating.
  • Output Protection: Anti-islanding protection, external AC overcurrent protection, output overvoltage protection with replaceable surge protection device (Type 2).

Environmental and Physical

  • Operating Temperature Range: -25 to +60°C (-13 to 140°F) with derating above 40°C (104°F)
  • Relative Humidity: 4% to 100% condensing
  • Sound Pressure Level: Typical 68 dB(A) at 1 meter
  • Max Operating Altitude: 2000 meters (6560 feet)
  • Cooling: Forced air
  • Dimensions: 869 x 1086 x 419 mm (34.2” x 42.7” x 16.5”)
  • Weight: 70 kg (154 lbs) for power module; ~55 kg (121 lbs) for wiring box; overall max 125 kg (276 lbs)
  • Mounting System: Mounting bracket for vertical and horizontal support

Communication and Interface

  • Embedded Communication Interfaces: 1x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2.4 GHz)
  • User Interface: 4 LEDs, Web User Interface
  • Communication Protocol: Modbus RTU/TCP (Sunspec compliant)
  • Commissioning Tool: Web User Interface, Mobile APP/APP for plant level
  • Remote Monitoring Services: Aurora Vision monitoring portal
  • Advanced Features: Embedded logging, direct telemetry data transferring to ABB cloud

Available Product Variants

  • Inverter Power Module: PVS-100-TL-POWER MODULE / PVS-120-TL-POWER MODULE
  • Wiring Box Versions:
    • SX2: Individual string monitoring, positive pole fuses, DC disconnect switches, surge arresters
    • SX: Individual string monitoring, both positive and negative pole fuses, DC disconnect switches, surge arresters
    • SY2: MPPT level input current monitoring, positive pole fuses, DC disconnect switches, surge arresters
    • SY: MPPT level input current monitoring, both positive and negative pole fuses, DC disconnect switches, surge arresters
    • S2: MPPT level input current monitoring, cable gland input, DC disconnect switches, surge arresters

Optional Accessories

  • AC Plate for Single Core Cables: Various individual AC cable glands
  • AC Plate for Multi Core Cables: Various individual AC cable glands
  • Pre-Charge Board Kit: Night time operation with restart capability
  • Grounding Kit: Allows connection of the negative input pole to the ground

Compliance and Standards

  • Safety and EMC Standards: IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-4
  • Grid Standards: Various international standards including CEI 0-16, IEC 61727, IEC 62116, etc.

Remarks

  • Technical Changes: FIMER reserves the right to make technical changes without prior notice.
  • Product Variants: Features not specifically listed in the present data sheet are not included in the product.
Bloga dön

İletişim formu