AEG AS-IC01-2 Series Grid-Tied Three-Phase Inverter Overview
General Description
The AEG AS-IC01-2 series inverters are designed for residential PV systems, offering compact design and high efficiency for small and medium-size installations. These inverters provide easy operability and comprehensive monitoring options, making them an ideal choice for various solar installations.
Key Features
-
Compact Design: Ideal for medium-size installations with flexible planning.
-
Efficiency: High efficiency ratings, ensuring optimal energy conversion.
-
Monitoring and Management: Integrated global monitoring system compatible with portable devices.
-
Ease of Installation: Features like built-in DC switch for safe and easy installation.
-
Warranty: Standard 5-year product warranty, with optional extensions to 10, 15, or 20 years.
Technical Specifications
Input (DC)
Model |
AS-IC01-4000-2 |
AS-IC01-5000-2 |
AS-IC01-6000-2 |
AS-IC01-8000-2 |
AS-IC01-10000-2 |
Nominal DC Input Power (W) |
4000 |
5000 |
6000 |
8000 |
10000 |
Max. DC Input Power (W) |
4200 |
5200 |
6300 |
8400 |
10400 |
Max. DC Input Voltage (V) |
900 |
900 |
900 |
1000 |
1000 |
Starting Voltage (V) |
200 |
200 |
200 |
300 |
300 |
MPPT Operating Voltage Range (V) |
200-800 |
200-800 |
200-800 |
200-800 |
200-800 |
Operation Voltage (V) |
210-800 |
260-800 |
310-800 |
350-800 |
400-800 |
Number of MPPT / String per MPPT |
2/1 |
2/1 |
2/1 |
2/1 |
2/1 |
Max. DC Current (A) per MPPT x Nr. of MPPT |
10 x 2 |
10 x 2 |
10 x 2 |
12 x 2 |
12.5 x 2 |
Isc PV (A) |
11 x 2 |
11 x 2 |
11 x 2 |
13 x 2 |
14 x 2 |
Maximum Backflow Current (A) |
0 |
0 |
0 |
0 |
0 |
DC Switch |
Integrated |
Integrated |
Integrated |
Integrated |
Integrated |
Output (AC)
Model |
AS-IC01-4000-2 |
AS-IC01-5000-2 |
AS-IC01-6000-2 |
AS-IC01-8000-2 |
AS-IC01-10000-2 |
Rated Output Power (W) |
4000 |
5000 |
6000 |
8000 |
10000 |
Max. Apparent Power SEmax (VA) |
4002 |
5018 |
6017 |
8038 |
9789 |
Max. AC Output Current (A) |
6.4 |
8.0 |
9.6 |
12.5 |
14 |
Maximum Output Overcurrent Protection (A) |
12.7 |
15.8 |
19 |
24.7 |
27.7 |
Maximum Output Fault Current (A) |
265A @ 34ms |
265A @ 34ms |
265A @ 34ms |
265A @ 34ms |
265A @ 34ms |
AC Inrush Current |
<10A |
<10A |
<10A |
<10A |
<10A |
Voltage (V) / Frequency (Hz) |
230400 Vac, 50 Hz (4751.5 Hz) |
230400 Vac, 50 Hz (4751.5 Hz) |
230400 Vac, 50 Hz (4751.5 Hz) |
230400 Vac, 50 Hz (4751.5 Hz) |
230400 Vac, 50 Hz (4751.5 Hz) |
Power Factor |
-0.9 ~ +0.9 (adjustable) |
-0.9 ~ +0.9 (adjustable) |
-0.9 ~ +0.9 (adjustable) |
-0.9 ~ +0.9 (adjustable) |
-0.9 ~ +0.9 (adjustable) |
THDi |
<3% (at rated power) |
<3% (at rated power) |
<3% (at rated power) |
<3% (at rated power) |
<3% (at rated power) |
AC Output |
Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) |
Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) |
Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) |
Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) |
Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) |
Mechanical Parameters
Model |
AS-IC01-4000-2 to AS-IC01-6000-2 |
AS-IC01-8000-2 to AS-IC01-10000-2 |
Dimensions (H x W x D, mm) |
530 x 360 x 150 |
575 x 360 x 150 |
Weight (kg) |
20 |
23 |
DC Terminal |
BC03A, BC03B |
BC03A, BC03B |
Installation |
Wall-mounting |
Wall-mounting |
Safety Certificates / EMC Category / Grid Standards |
IEC 62109-1 (ed.1), IEC 62109-2 (ed.1), EN 62109-1:2010, EN 62109-2:2011, EN 61000-6-3:2007+A1:2011, EN 61000-6-2:2005; VDE-AR-N 4105:2018, DIN VDE V 0124-100:20, EN 50549-1:2019, C10/11:2019 |
IEC 62109-1 (ed.1), IEC 62109-2 (ed.1), EN 62109-1:2010, EN 62109-2:2011, EN 61000-6-3:2007+A1:2011, EN 61000-6-2:2005; VDE-AR-N 4105:2018, DIN VDE V 0124-100:20, EN 50549-1:2019, C10/11:2019 |
Noise (dB) |
≤30 |
<50 |
System
| Cooling | Natural cooling | Air cooling | | Max. Efficiency (%) | 97.20 - 98.20 | | Euro-Efficiency (%) | 97.00 - 97.60 | | MPPT Efficiency (%) | 99.90 | | Protection Rating | IP65 | | Power Consumption at Night (W) | <1 | | Topology and Isolation Mode | Non-isolated, transformerless | | Operating Temperature | -25°C ~ +60°C (derate after 45°C) | | Relative Humidity | 4 ~100%, condensation | | Max. Altitude (m) | ≤2000 (derate if the altitude >2000) | | Overvoltage Protection Class and Safety Class | AC
, PV
; Safety Class I | |
Protection | Input overvoltage protection, input overcurrent protection, DC isolation monitoring, DC monitoring, grounding fault current monitoring, grid monitoring, island protection, short circuit protection, overheating protection |
Display and Communication
| Display | LCD | | System Language | English, German, Dutch | | Communication | RS485 + WiFi (Standard), Ethernet (Optional) |
Warranty
| Product Warranty | 5 years (optional: 10/15/20 years) |