PSI-J3000-HY | PSI-J4000-HY | PSI-J5000-HY | PSI-J6000-HY Hybrid Inverter Characteristics
NOCTIS LINE | SINGLE-PHASE HYBRID INVERTER
-
Charging Current: 100A
- Practical and Silent
-
Storage Capacity: Up to 28.8 kWh
-
Website: www.peimar.com
General Information
Feature |
Specification |
Topology |
Transformerless |
Operating temperature range |
-25°C to +60°C (45°C to 60°C with derating) |
Cooling method |
Natural convection |
Environmental humidity |
0% to 100% non-condensing |
Altitude |
Up to 4000 m (with derating above 3000 m) |
Noise |
< 29 dBA |
Protection class |
IP65 |
Mounting |
Wall mounting bracket |
Dimensions (H x W x D) |
470 x 470 x 190 mm |
Net weight |
23 kg |
Warranty |
5 Years |
DC Input
Specification |
PSI-J3000-HY |
PSI-J4000-HY |
PSI-J5000-HY |
PSI-J6000-HY |
Maximum DC power |
4500 W |
6000 W |
7500 W |
9000 W |
Maximum DC voltage |
600 V |
600 V |
600 V |
600 V |
MPPT voltage range |
90 - 550 V |
90 - 550 V |
90 - 550 V |
90 - 550 V |
Nominal DC voltage |
360 V |
360 V |
360 V |
360 V |
Minimum DC voltage |
80 V |
80 V |
80 V |
80 V |
Start voltage |
120 V |
120 V |
120 V |
120 V |
Maximum DC input current |
12.5 / 12.5 A |
12.5 / 12.5 A |
12.5 / 12.5 A |
12.5 / 12.5 A |
Maximum short-circuit current |
15 / 15 A |
15 / 15 A |
15 / 15 A |
15 / 15 A |
Number of DC inputs per MPPT |
1 / 1 |
1 / 1 |
1 / 1 |
1 / 1 |
Number of MPPT trackers |
2 |
2 |
2 |
2 |
DC switch (DC21B) |
Integrated |
Integrated |
Integrated |
Integrated |
Battery Parameters
Feature |
Specification |
Compatible batteries (not included) |
Peimar PSI-J51-48-BT, PSI-DN-PBM-H2.5-LV, PSI-DN-PBM-H5.0-LV, PSI-DN-PB-F7.5-LV, PSI-DN-PB-F10.0-LV |
Possible battery configurations |
Up to 4 PSI-J51-48-BT in parallel, Max. 1 PSI-DN-PBM-H2.5-LV, Up to 4 PSI-DN-PBM-H5.0-LV in parallel, Up to 4 PSI-DN-PB-F7.5-LV in parallel, Up to 3 PSI-DN-PB-F10.0-LV in parallel |
Battery type |
Lithium battery (LiFePO4) |
Input voltage range |
48 V / 42 - 58.5 V |
Maximum charge/discharge current |
60 / 60 A (PSI-J3000-HY, PSI-J4000-HY) 100 / 100 A (PSI-J5000-HY, PSI-J6000-HY) |
Charge mode control |
2 stages |
AC Output
Specification |
PSI-J3000-HY |
PSI-J4000-HY |
PSI-J5000-HY |
PSI-J6000-HY |
Nominal AC power |
3000 W |
4000 W |
5000 W |
6000 W |
Maximum AC power |
3000 VA |
4000 VA |
5000 VA |
6000 VA |
Nominal AC current |
13.1 A |
17.4 A |
21.8 A |
26.1 A |
Maximum AC current |
13.6 A |
18.2 A |
22.7 A |
27.3 A |
Grid voltage |
220, 230, 240 V /180 - 280 V |
|
|
|
Grid frequency |
50 Hz, 60 Hz / ±5 Hz |
|
|
|
Power factor (cos φ) |
0.8 capacitive - 0.8 inductive |
|
|
|
Total harmonic distortion (THDi) |
< 3% |
|
|
|
Connection |
Single-phase 1L+N+PE |
|
|
|
AC Output (Back-Up Mode)
Specification |
PSI-J3000-HY |
PSI-J4000-HY |
PSI-J5000-HY |
PSI-J6000-HY |
Maximum AC power |
3000 W |
5000 W |
|
|
Maximum peak power |
3600 VA, 10 sec |
6000 VA, 10 sec |
|
|
Voltage |
220 V, 230 V, 240 V |
|
|
|
Frequency |
50 Hz, 60 Hz |
|
|
|
Total harmonic distortion |
< 3% |
|
|
|
Connection |
Single-phase 1L+N+PE |
|
|
|
Meter
Feature |
Specification |
Compatible meter |
Peimar PSI-J-1PMETER (not included) |
Functionality |
Measure electrical parameters of draw and injection |
Communication data cable (not included) |
Twisted pair cable compatible with RJ45 plug and meter terminal block |
Efficiency
Feature |
Specification |
Maximum efficiency |
97.6% |
European efficiency |
97.0% |
Maximum battery charge efficiency |
94.6% |
Protection
Feature |
Specification |
AC short-circuit current protection |
Integrated |
Overload protection |
Integrated |
DC over/under voltage protection |
Integrated |
AC over/under voltage protection |
Integrated |
AC over/under frequency protection |
Integrated |
Charge/discharge period setting |
Integrated |
Interface
Feature |
Specification |
AC connection |
Terminal block |
Photovoltaic input |
MC4 |
Backup line connection |
Terminal block |
Battery connection |
Ring terminals |
Display |
LCD |
Communication mode |
Wi-Fi (Peimar PSI-J-H-WIFI module included) |
Communication ports (internal and battery) |
USB (for Wi-Fi/Ethernet module) / CAN (battery communication) / RS485 (meter communication) |