KACO Blueplanet Hybrid 10.0 TL3 Inverter
Overview
The KACO Blueplanet Hybrid 10.0 TL3 is a versatile hybrid inverter designed for residential and small commercial battery storage and solar PV systems. It allows for efficient energy storage and utilization, offering robust performance in both on-grid and off-grid applications.
Key Features
-
10 kW Inverter Output: Supports 10 kW output in both grid-tied and battery operation modes.
-
3-Phase Operation: Suitable for mains parallel operation and off-grid capability.
-
High Efficiency: Over 98% efficiency with outstanding partial load behavior.
-
Integrated Battery Management: Ensures optimal battery performance and longevity.
-
Flexible Integration: Two MPP trackers for easy integration with solar PV systems.
-
Easy Installation: Lightweight design with an adapter plate for wall mounting.
Technical Specifications
PV Input (DC)
Specification |
Value |
Max. recommended PV generator power |
15,000 W |
Number of inputs / MPP Tracker |
2 |
Nom. / max. DC voltage |
680 V DC / 900 V DC |
Start-up voltage |
240 V DC |
MPP range @ rated power |
420 V DC – 740 V DC |
Operating range |
200 V DC – 850 V DC |
Max. input current per MPP Tracker |
12 A |
Max. short-circuit current Isc max |
15 A per input channel |
Overload behavior |
Shift of working point |
Efficiency
Specification |
Value |
PV (DC) to grid (AC) [max.] |
>98.1% |
PV (DC) to grid (AC) [EU] |
>97.8% |
PV (DC) to battery (DC) [max.] |
>98.8% |
Battery (DC) to grid (AC) [max.] |
>97.7% |
Night-time consumption (off) |
<0.1 W |
Idle state consumption |
<20 W |
Battery Mode Input (DC)
Specification |
Value |
Nom. DC voltage |
425 V DC |
Max. charge / discharge current |
25 A |
Battery voltage min. - max. |
96 V DC - 450 V DC |
Galvanic isolation |
No |
Safeguarding |
Safety-fuse, cut-off relay |
Battery Mode AC-Connection
Specification |
Value |
Nom. charging power |
9990 W |
Nom. discharging power |
9990 W |
Voltage shape in off-grid mode |
True sinus |
Number of current phases |
3 |
Grid Feed-In (AC)
Specification |
Value |
Nom. power AC |
9,990 W |
Max. power AC |
11,000 VA |
Number of phases |
3 |
Typ. power per phase to grid |
3,330 W |
Max. AC current per phase |
16.1 A RMS |
Feed-in sym. / asym. |
- |
Nom. AC voltage |
210 – 264 V AC |
AC voltage range |
184 – 264 V AC |
Grid frequency range |
47.5 Hz – 51.5 Hz |
Power factor |
0.9c – 0.9i |
Topology |
Transformerless |
Load compensation |
200 ms |
Initial short-circuit alternating current |
16.4 A |
Max. power AC in off-grid mode |
Max. 4,000 W per phase and max. 10,000 W phase sum |
Inrush current |
1.7 A |
General Data
Specification |
Value |
Dimension (WxHxD) |
610 x 552 x 200 mm |
Weight |
37 kg |
Display |
LCD |
DC disconnecting switch |
Integrated |
RC Protective Device |
Integrated (type B) |
Protective relais |
Integrated (VDE AR-N 4105) |
Battery breaker |
Integrated |
Operating temperature range |
+5 to +40°C |
Installation altitude |
0 – 2000 m |
Installation humidity |
20 - 90% RH (non-condensing) |
Protection (in off-grid mode) |
PE, RCD Type B ** |
Noise emission |
<35 dB(A) |
Over temperature behavior |
Power reduction |
Degree of protection |
IP20 |
Case material |
Aluminium |
PWM frequency |
20 kHz |
On-grid operation |
Grid-commutated |
Energy source for battery charging |
PV, grid |
Pollution degree |
PD2 |
Connections
Specification |
Value |
DC connection for battery |
PhoenixContact Sunclix |
DC connection for PV |
PhoenixContact Sunclix |
AC connection |
5-Pole PhoenixContact - Art. 1409205 |
AC connection max. wire cross section |
4 mm² |
Communication ports |
2 x RJ45 (RS485), 1 x RJ45 (Ethernet) external |
Supported Devices | Energy Storage | BYD Battery-Box HVS 5.1-10.2 and HVM 8.3-22.1, Energy Depot DOMUS 2.5 | | Meter | Blueplanet hy-switch |
Energy Conversion Modes
Conversion Mode |
Supported |
PV (DC) to grid (AC) |
Yes |
PV (DC) to battery (DC) |
Yes |
PV (DC) to grid (AC) + battery (DC) |
Yes (with external EMS) |
Battery (DC) to grid (AC) |
Yes |
Certifications and Standards
- Safety: IEC 62109-1, IEC 62109-2
- EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
- VDE 0126, VDE AR-N 4105
Notes
- Power reduction of 2% per 100 m above 1000 m altitude.
- If two or more inverters are installed in the same grid or emergency power/off-grid operation is in use, a separate residual current device (RCD type B) is compulsory.