(CTRL + F) for fast search.

KACO Blueplanet Hybrid 10.0 TL3 Inverter Manual

KACO Blueplanet Hybrid 10.0 TL3 Inverter

Overview

The KACO Blueplanet Hybrid 10.0 TL3 is a versatile hybrid inverter designed for residential and small commercial battery storage and solar PV systems. It allows for efficient energy storage and utilization, offering robust performance in both on-grid and off-grid applications.

Key Features

  • 10 kW Inverter Output: Supports 10 kW output in both grid-tied and battery operation modes.
  • 3-Phase Operation: Suitable for mains parallel operation and off-grid capability.
  • High Efficiency: Over 98% efficiency with outstanding partial load behavior.
  • Integrated Battery Management: Ensures optimal battery performance and longevity.
  • Flexible Integration: Two MPP trackers for easy integration with solar PV systems.
  • Easy Installation: Lightweight design with an adapter plate for wall mounting.

Technical Specifications

PV Input (DC)

Specification Value
Max. recommended PV generator power 15,000 W
Number of inputs / MPP Tracker 2
Nom. / max. DC voltage 680 V DC / 900 V DC
Start-up voltage 240 V DC
MPP range @ rated power 420 V DC – 740 V DC
Operating range 200 V DC – 850 V DC
Max. input current per MPP Tracker 12 A
Max. short-circuit current Isc max 15 A per input channel
Overload behavior Shift of working point

Efficiency

Specification Value
PV (DC) to grid (AC) [max.] >98.1%
PV (DC) to grid (AC) [EU] >97.8%
PV (DC) to battery (DC) [max.] >98.8%
Battery (DC) to grid (AC) [max.] >97.7%
Night-time consumption (off) <0.1 W
Idle state consumption <20 W

Battery Mode Input (DC)

Specification Value
Nom. DC voltage 425 V DC
Max. charge / discharge current 25 A
Battery voltage min. - max. 96 V DC - 450 V DC
Galvanic isolation No
Safeguarding Safety-fuse, cut-off relay

Battery Mode AC-Connection

Specification Value
Nom. charging power 9990 W
Nom. discharging power 9990 W
Voltage shape in off-grid mode True sinus
Number of current phases 3

Grid Feed-In (AC)

Specification Value
Nom. power AC 9,990 W
Max. power AC 11,000 VA
Number of phases 3
Typ. power per phase to grid 3,330 W
Max. AC current per phase 16.1 A RMS
Feed-in sym. / asym. -
Nom. AC voltage 210 – 264 V AC
AC voltage range 184 – 264 V AC
Grid frequency range 47.5 Hz – 51.5 Hz
Power factor 0.9c – 0.9i
Topology Transformerless
Load compensation 200 ms
Initial short-circuit alternating current 16.4 A
Max. power AC in off-grid mode Max. 4,000 W per phase and max. 10,000 W phase sum
Inrush current 1.7 A

General Data

Specification Value
Dimension (WxHxD) 610 x 552 x 200 mm
Weight 37 kg
Display LCD
DC disconnecting switch Integrated
RC Protective Device Integrated (type B)
Protective relais Integrated (VDE AR-N 4105)
Battery breaker Integrated
Operating temperature range +5 to +40°C
Installation altitude 0 – 2000 m
Installation humidity 20 - 90% RH (non-condensing)
Protection (in off-grid mode) PE, RCD Type B **
Noise emission <35 dB(A)
Over temperature behavior Power reduction
Degree of protection IP20
Case material Aluminium
PWM frequency 20 kHz
On-grid operation Grid-commutated
Energy source for battery charging PV, grid
Pollution degree PD2

Connections

Specification Value
DC connection for battery PhoenixContact Sunclix
DC connection for PV PhoenixContact Sunclix
AC connection 5-Pole PhoenixContact - Art. 1409205
AC connection max. wire cross section 4 mm²
Communication ports 2 x RJ45 (RS485), 1 x RJ45 (Ethernet) external

Supported Devices | Energy Storage | BYD Battery-Box HVS 5.1-10.2 and HVM 8.3-22.1, Energy Depot DOMUS 2.5 | | Meter | Blueplanet hy-switch |

Energy Conversion Modes

Conversion Mode Supported
PV (DC) to grid (AC) Yes
PV (DC) to battery (DC) Yes
PV (DC) to grid (AC) + battery (DC) Yes (with external EMS)
Battery (DC) to grid (AC) Yes

Certifications and Standards

  • Safety: IEC 62109-1, IEC 62109-2
  • EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
  • VDE 0126, VDE AR-N 4105

Notes

  • Power reduction of 2% per 100 m above 1000 m altitude.
  • If two or more inverters are installed in the same grid or emergency power/off-grid operation is in use, a separate residual current device (RCD type B) is compulsory.
Zurück zum Blog

Kontaktformular