Input Side |
|
|
|
Absolute Maximum DC Input Voltage |
600 V |
600 V |
600 V |
Start-up DC Input Voltage |
120 V (adj. 120…150 V) |
150 V (adj. 120…250 V) |
150 V (adj. 120…250 V) |
Operating DC Input Voltage Range |
0.7 x Vstart...580 V (min 90 V) |
0.7 x Vstart...580 V (min 90 V) |
0.7 x Vstart...580 V (min 90 V) |
Rated DC Input Voltage |
185 V |
300 V |
300 V |
Rated DC Input Power |
1500 W |
2500 W |
3300 W |
Number of Independent MPPT |
1 |
1 |
1 |
Maximum DC Input Current (Idcmax) |
10.0 A |
10.0 A |
10.0 A |
Maximum Input Short Circuit Current |
12.5 A |
12.5 A |
12.5 A |
Number of DC Input Pairs per MPPT |
1 |
1 |
1 |
DC Connection Type |
Quick Fit PV Connector |
Quick Fit PV Connector |
Quick Fit PV Connector |
Input Protection |
Reverse polarity protection, input over voltage protection (varistor), photovoltaic array isolation control |
|
|
Output Side |
|
|
|
AC Grid Connection Type |
Single-phase |
Single-phase |
Single-phase |
Rated AC Power (Pacr@cosφ=1) |
1200 W |
2000 W |
3000 W |
Maximum AC Output Power (Pacmax @cosφ=1) |
1200 W |
2000 W |
3000 W |
Rated AC Grid Voltage |
230 V |
230 V |
230 V |
AC Voltage Range |
180...264 V |
180...264 V |
180...264 V |
Maximum AC Output Current (Iac,max) |
5.5 A |
10.0 A |
14.5 A |
Rated Output Frequency |
50/60 Hz |
50/60 Hz |
50/60 Hz |
Output Frequency Range |
47...53/57...63 Hz |
47...53/57...63 Hz |
47...53/57...63 Hz |
Nominal Power Factor |
> 0.995, adj. ± 0.1 - 1 (over/under excited) |
> 0.995, adj. ± 0.1 - 1 (over/under excited) |
> 0.995, adj. ± 0.1 - 1 (over/under excited) |
Total Current Harmonic Distortion |
< 3% |
< 3% |
< 3% |
AC Connection Type |
Female connector from panel |
Female connector from panel |
Female connector from panel |
Output Protection |
Anti-islanding protection, maximum external AC overcurrent protection, output overvoltage protection (varistor) |
|
|
Operating Performance |
|
|
|
Maximum Efficiency (ηmax) |
94.8% |
96.7% |
96.7% |
Weighted Efficiency (EURO/CEC) |
92.0% |
95.0% |
95.0% |
Feed-in Power Threshold |
8 W |
8 W |
8 W |
Night Consumption |
<0.4 W |
<0.4 W |
<0.4 W |
Embedded Communication |
|
|
|
Embedded Communication Interface |
Wireless |
Wireless |
Wireless |
Embedded Communication Protocol |
ModBus TCP (SunSpec) |
ModBus TCP (SunSpec) |
ModBus TCP (SunSpec) |
Commissioning Tool |
Web User Interface, Aurora Manager Lite |
Web User Interface, Aurora Manager Lite |
Web User Interface, Aurora Manager Lite |
Monitoring |
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile, Energy Viewer |
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile, Energy Viewer |
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile, Energy Viewer |
Optional Boards |
UNO-DM-COM kit |
UNO-DM-COM kit |
UNO-DM-COM kit |
Optional Communication Interfaces |
RS485, Alarm/Load manager relay, Remote ON/OFF |
RS485, Alarm/Load manager relay, Remote ON/OFF |
RS485, Alarm/Load manager relay, Remote ON/OFF |
Optional Communication Protocols |
ModBus RTU (SunSpec), Aurora Protocol |
ModBus RTU (SunSpec), Aurora Protocol |
ModBus RTU (SunSpec), Aurora Protocol |
Environmental |
|
|
|
Ambient Temperature Range |
-25...+60°C / -13...140°F with derating above 50°C/122°F |
-25...+60°C / -13...140°F with derating above 50°C/122°F |
-25...+60°C / -13...140°F with derating above 50°C/122°F |
Relative Humidity |
0...100% condensing |
0...100% condensing |
0...100% condensing |
Acoustic Noise Emission Level |
50 dBA @ 1 m |
50 dBA @ 1 m |
50 dBA @ 1 m |
Maximum Operating Altitude |
2000 m / 6560 ft |
2000 m / 6560 ft |
2000 m / 6560 ft |
Environmental Protection Rating |
IP65 |
IP65 |
IP65 |
Cooling |
Natural |
Natural |
Natural |
Physical |
|
|
|
Dimensions (H x W x D) |
553 x 418 x 175 mm / 21.8” x 16.5” x 6.9” |
553 x 418 x 175 mm / 21.8” x 16.5” x 6.9” |
553 x 418 x 175 mm / 21.8” x 16.5” x 6.9” |
Weight |
15 kg / 33 lbs |
15 kg / 33 lbs |
15 kg / 33 lbs |
Mounting System |
Wall bracket |
Wall bracket |
Wall bracket |
Safety |
|
|
|
Isolation Level |
Transformerless |
Transformerless |
Transformerless |
Marking |
CE, RCM |
CE, RCM |
CE, RCM |
Safety and EMC Standard |
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3 |
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3 |
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3 |
Grid Standard |
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, G98-1, G99-1, RD 413, ITC-BT-40, AS/NZS 4777.2, IEC 61727, IEC 62116 |
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, G98-1, G99-1, RD 413, ITC-BT-40, AS/NZS 4777.2, IEC 61727, IEC 62116 |
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, G98-1, G99-1, RD 413, ITC-BT-40, AS/NZS 4777.2, IEC 61727, IEC 62116 |