Ingecon SUN 3TL-6TL M2 Manual


Από Erik Zaikin
Ανάγνωση σε 3 λεπτά


INGECON® SUN 1Play TL M Series

Overview

The INGECON® SUN 1Play TL M Series includes single-phase PV inverters designed for residential self-consumption systems. They offer one or two Maximum Power Point Trackers (MPPT) to maximize energy harnessed from the PV array, even in challenging conditions like partial shading.

Key Features

  • Maximum Efficiency: One or two independent MPPT inputs for optimal energy harnessing.
  • Plug & Play Technology: Easy and quick installation.
  • Rugged Design: Die-cast aluminum casing suitable for indoor and outdoor applications (IP65).
  • Ease of Maintenance: Internal datalogger and remote control options.
  • Software Included: INGECON® SUN Monitor and iSun Monitor for monitoring over the internet.
  • Communications: Ethernet and Wi-Fi as standard.
  • Warranty: Standard 5-year warranty, extendable up to 25 years.

Main Features

  • EMS inside.
  • Single or double MPPT system.
  • Ethernet and Wi-Fi communications supplied as standard.
  • Remote configuration and upgrade.
  • Software INGECON® SUN Monitor for PV plant monitoring.
  • LED status indicators.
  • Easy maintenance.
  • Plug & Play technology.
  • Suitable for indoor and outdoor installations (IP65).
  • High temperature performance.
  • Compact design.
  • Configurable language, rated voltage, and country code via app.
  • Compatible with high power modules.

Protections

  • Reverse polarity protection.
  • Short circuits and overloads at the output.
  • Anti-islanding with automatic disconnection.
  • Insulation faults.
  • Output overvoltages with type III surge arresters.

Optional Accessories

  • Self-consumption kit.

Benefits

  • Greater performance thanks to the MPPT system.
  • Easy maintenance.
  • Higher inverter life expectancy.
  • Waterproof and dustproof (IP65).
  • Anti-corrosion with C5 protection class.

All models feature DC and AC surge arresters type III and an integrated DC switch.

Technical Specifications

Specification 3TL M2 6TL M2
Input (DC)
Recommended PV array power range 3.09 - 4.5 kWp 6.18 - 9 kWp
Voltage range MPPT 50 - 490 V 70 - 540 V
Start input voltage 70 V 90 V
Maximum voltage 500 V 550 V
Rated input voltage 360 V 360 V
Max. Short circuit current 20 A 40 A (2x20 A)
Maximum current 15 A 30 A (2x15 A)
Inputs with PV connectors 1 2 (1/1)
Number of MPPTs 1 2
Output (AC)
Rated power 3 kW 6 kW
Max. apparent power 3.3 kVA 6 kVA
Max. active power (PF = 1) 3.3 kW 6 kW
Max. output current 15 A 27.3 A
Rated voltage 220/230 V 220/230 V
Voltage range 160 - 300 V (Adjustable) 160 - 300 V (Adjustable)
Frequency 50 / 60 Hz 50 / 60 Hz
Type of grid TT / TN TT / TN
Power Factor > 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG) > 0.99 Rated power (Adjustable 0.8 LD - 0.8 LG)
THD < 3% @ Rated power < 3% @ Rated power
Efficiency
Maximum efficiency 97% 97%
Euroefficiency 96% 96.10%
General Information
Refrigeration system Natural ventilation Natural ventilation
Consumption at night 10 W 10 W
Ambient temperature -25°C to 60°C -25°C to 60°C
Relative humidity (non-condensing) 0 - 100 % 0 - 100 %
Protection class IP65 IP65
Marking CE CE
Acoustic emissions 30 dB 30 dB
Max. Operating altitude 4,000 m 4,000 m
EMC and security standards EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2
Grid connection standards IEC 61727:2004, IEC 62116:2014, EN 50549-1:2019, UNE 217002:2020, UNE 217001:2020, NTS SEPE 2.1 type A, CEI 0-21 v1 November 2022 (including Allegato B), VDE-AR-N 4105:2018 IEC 61727:2004, IEC 62116:2014, EN 50549-1:2019, UNE 217002:2020, UNE 217001:2020, NTS SEPE 2.1 type A, CEI 0-21 v1 November 2022 (including Allegato B), VDE-AR-N 4105:2018
Integrated Elements
DC switch Yes Yes
Anti-islanding protection Yes Yes
AC overcurrent protection Yes Yes
AC short-circuit protection Yes Yes
DC reverse connection Yes Yes
DC & AC surge arresters, type III Yes Yes
Insulation detection Yes Yes
Leakage current protection Yes Yes

Dimensions and Weight

  • 3TL M2:
    • Dimensions: 344 x 320 x 107 mm
    • Weight: 6.7 kg
  • 6TL M2:
    • Dimensions: 347 x 350 x 137 mm
    • Weight: 8.7 kg

Notes

  • In Spain, the maximum active power will be the same as the rated power.
  • The range of output voltage and frequency may vary depending upon different grid codes.

For further information: