PSI-X1P3000-HY | PSI-X1P5000-HY | PSI-X1P6000-HY Hybrid Inverter Characteristics
NOCTIS LINE | SINGLE-PHASE HYBRID INVERTER
-
Display: For fast commissioning and direct control
-
Peimar X Portal: Remote data reading and programming
- 2 MPPTs
- IP65 Protection
General Information
Feature |
Specification |
Topology |
Transformerless |
Standby power consumption |
< 3 W |
Operating temperature range |
-35°C to +60°C (derating from +45°C) |
Cooling method |
Natural convection |
Environmental humidity |
0% to 100% non-condensing |
Storage temperature |
-40°C to +65°C |
Altitude |
Up to 3000 m |
Noise |
< 30 dB |
Protection class |
IP65 |
Mounting |
Wall mounting bracket |
Dimensions (H x W x D) |
482 x 417 x 181 mm |
Net weight |
22 kg |
Warranty |
10 Years |
DC Input
Specification |
PSI-X1P3000-HY |
PSI-X1P5000-HY |
PSI-X1P6000-HY |
Maximum DC power |
4500 W |
7500 W |
9000 W |
Maximum DC voltage |
600 V |
600 V |
600 V |
MPPT voltage range |
70 - 550 V |
70 - 550 V |
70 - 550 V |
Nominal DC voltage |
360 V |
360 V |
360 V |
Start voltage |
90 V |
90 V |
90 V |
Maximum DC input current |
14 / 14 A |
14 / 14 A |
14 / 14 A |
Maximum short-circuit current |
16 / 16 A |
16 / 16 A |
16 / 16 A |
Number of DC inputs per MPPT |
1 / 1 |
1 / 1 |
1 / 1 |
Number of MPPT trackers |
2 |
2 |
2 |
DC switch (DC-PV2) |
Integrated |
Integrated |
Integrated |
Battery Parameters
Feature |
Specification |
Compatible storage devices (not included) |
Peimar PSI-X-PRL-BMS (parallel BMS), Peimar PSI-X-BT-5.8MST-HV (Master Battery), Peimar PSI-X-BT-5.8SLV-HV (Slave Battery) |
Possible battery configurations |
See table below |
Battery type |
Lithium battery (LiFePO4) |
Input voltage range |
80 - 480 V |
Maximum continuous charge/discharge current |
30 / 30 A |
Possible Battery Configurations
Configuration |
Master Batteries |
Slave Batteries |
5.8 kWh |
1 Master PSI-X-BT-5.8MST-HV |
|
11.5 kWh |
1 Master PSI-X-BT-5.8MST-HV |
1 Slave PSI-X-BT-5.8SLV-HV |
17.3 kWh |
1 Master PSI-X-BT-5.8MST-HV |
2 Slave PSI-X-BT-5.8SLV-HV |
5.8 kWh (Parallel BMS) |
1 PSI-X-PRL-BMS |
1 Slave PSI-X-BT-5.8SLV-HV |
11.5 kWh (Parallel BMS) |
1 PSI-X-PRL-BMS |
2 Slave PSI-X-BT-5.8SLV-HV |
17.3 kWh (Parallel BMS) |
1 PSI-X-PRL-BMS |
3 Slave PSI-X-BT-5.8SLV-HV |
11.5 kWh (Port B1 + B2) |
1 PSI-X-PRL-BMS |
1 PSI-X-BT-5.8SLV-HV (B1) + 1 PSI-X-BT-5.8SLV-HV (B2) |
23.0 kWh (Port B1 + B2) |
1 PSI-X-PRL-BMS |
2 PSI-X-BT-5.8SLV-HV (B1) + 2 PSI-X-BT-5.8SLV-HV (B2) |
34.6 kWh (Port B1 + B2) |
1 PSI-X-PRL-BMS |
3 PSI-X-BT-5.8SLV-HV (B1) + 3 PSI-X-BT-5.8SLV-HV (B2) |
AC Output
Specification |
PSI-X1P3000-HY |
PSI-X1P5000-HY |
PSI-X1P6000-HY |
Nominal AC power |
3000 W |
5000 W |
6000 W |
Maximum AC power |
3300 VA |
5500 VA |
6600 VA |
Nominal AC current |
13.1 A |
21.7 A |
26.1 A |
Maximum AC current |
14.4 A |
23.9 A |
28.6 A |
Grid nominal voltage |
220, 230, 240 V / 180 - 270 V |
|
|
Grid nominal frequency |
50, 60 Hz |
|
|
Power factor (cos φ) |
0.8 capacitive - 0.8 inductive |
|
|
Total harmonic distortion (THDi) |
< 2 % |
|
|
Connection |
Single-phase 1L + N + PE |
|
|
AC Output (Back-Up Mode)
Specification |
PSI-X1P3000-HY |
PSI-X1P5000-HY |
PSI-X1P6000-HY |
Nominal AC power |
3000 W |
5000 W |
6000 W |
Maximum peak power |
3600 VA, 1 hour |
6000 VA, 1 hour |
7200 VA, 10 min |
Nominal voltage |
230 V |
|
|
Frequency |
50, 60 Hz |
|
|
Switching time |
< 10 ms |
|
|
Total harmonic distortion (THDv) |
< 2 % (linear load) |
|
|
Connection |
Single-phase 1L + N + PE |
|
|
Meter
Feature |
Specification |
Compatible meter |
PSI-X-1PMETER-ZI (not included, up to 80 A) |
Functionality |
Measure electrical parameters of draw and injection, necessary for external load management and charge/discharge of the storage system |
Efficiency
Feature |
Specification |
MPPT efficiency |
99.9 % |
Maximum efficiency |
97.6 % |
European efficiency |
97.0 % |
Battery charge/discharge efficiency |
97.0 % |
Protection
Feature |
Specification |
AC and DC over/under voltage protection |
Integrated |
Reverse current monitoring |
Integrated |
Anti-islanding protection |
Integrated |
Overload protection |
Integrated |
Over-temperature protection |
Integrated |
Reverse battery polarity protection |
Integrated |
Overvoltage SPD protection |
Integrated |
Interface
Feature |
Specification |
AC connection |
Terminal block |
Photovoltaic input |
MC4 or compatible connectors |
Backup line connection |
Terminal block |
Battery connection |
Connectors |
Display |
LCD |
Communication mode |
Wi-Fi (PSI-X-H-WIFI 3.0 module included) / LAN (optional PSI-X-H-ETH 3.0 module) |
Communication ports (internal and battery) |
Dongle (USB port for Wi-Fi/Ethernet module) / BMS (RJ45 port for battery communication) / Meter / CT (RJ45 port for meter communication) / CAN (RJ45 port for parallel function) / COM / LCD (RJ45 port for external communication) |
Note: The technical data, information, and illustrations contained in this document are for indicative purposes only. Peimar reserves the right to modify the data, drawings, and information at any time without prior notice.