CL 30/33/50 String Inverter: Solar Solutions for Commercial and Industrial Buildings
The CL 30/33/50 inverters by Schneider Electric offer scalable and flexible solutions for commercial and industrial buildings, including carports. These inverters are designed to optimize performance, ease of installation, and remote management.
Key Features
Optimum System Performance
-
Multiple MPPT Inputs:
- CL 30/33: 3 MPPTs
- CL 50: 5 MPPTs
- High Efficiency: Up to 98.7% peak efficiency.
- DC/AC Ratio: Supports up to a 1.5 DC/AC ratio.
- Surge Protection: DC/AC surge protection ensures system durability.
Flexibility
- Remote Asset Management: Compatible with Insight for easier monitoring, troubleshooting, and management.
Ease of Installation
- Lightweight: Easy to install due to low weight.
- Complete Solution: Compatible with Schneider Electric’s broad range of low voltage products.
- AC Coupling: Compatible with Schneider Electric CIB storage products.
Insight Compatibility
- Setup and Configuration: Simplified installation process.
- Remote Monitoring and Control: Advanced data security with a web and mobile app.
- Multi-Site Management: Ideal for installers and portfolio managers.
Technical Specifications
Features | CL 30 | CL 33 | CL 50 |
---|---|---|---|
Input (DC) | |||
Max. PV input voltage | 1100 V | 1100 V | 1100 V |
Min. PV input voltage / Start-up voltage | 200 V / 250 V | 200 V / 250 V | 200 V / 250 V |
Nominal PV input voltage | 585 V | 585 V | 585 V |
MPPT voltage range | 200 – 1000 V | 200 – 1000 V | 200 – 1000 V |
MPPT voltage range for nominal power | 550 – 850 V | 550 – 850 V | 550 – 850 V |
No. of independent MPPT inputs | 3 | 3 | 5 |
Max. number of PV strings per MPPT | 2 | 2 | 2 |
Max. PV input current | 78 A | 78 A | 130 A |
Max. DC short-circuit current | 120 A | 120 A | 200 A |
Max. PV input | 45 kW | 49.5 kW | 76 kW |
DC Disconnect Switch | Yes (1 switch) | Yes (1 switch) | Yes (2 switches) |
Output (AC) | |||
Nominal AC output power | 29.9 kW | 33 kW | 50 kW |
Max AC output power | 29.9 kVA | 36.3 kVA | 55 kVA (50 kVA for Australia) |
Max AC output current | 48.15 A | 55.2 A | 83.6 A (80.5 A for Australia) |
Nominal AC voltage | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V |
AC voltage range | 312 – 528 V | 312 – 528 V | 312 – 528 V |
Nominal grid frequency / range | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
THD | < 3 % (at nominal power) | < 3 % (at nominal power) | < 3 % (at nominal power) |
Power factor | > 0.99 / 0.8 leading – 0.8 lagging | > 0.99 / 0.8 leading – 0.8 lagging | > 0.99 / 0.8 leading – 0.8 lagging |
Feed-in phases | 3 | 3 | 3 |
Efficiency | |||
Max efficiency | 98.6% | 98.7% | 98.7% |
General Specifications | |||
Dimensions (WHD) | 702595310 mm | 702595310 mm | 782645310 mm |
Weight | 50 kg | 50 kg | 62 kg |
Isolation method | Transformerless | Transformerless | Transformerless |
Protection level | IP66 | IP66 | IP66 |
Operating temperature | -30 to 60°C (derating > 45°C) | -30 to 60°C (derating > 45°C) | -30 to 60°C (derating > 45°C) |
Cooling | Smart forced air cooling | Smart forced air cooling | Smart forced air cooling |
Communication | RS485 | RS485 | RS485 |
Warranty | Please refer to solar.se.com for latest warranty details | Please refer to solar.se.com for latest warranty details | Please refer to solar.se.com for latest warranty details |
Protection Features
- DC Reverse Connection Protection
- AC Short Circuit Protection
- Leakage Current Protection
- Grid Monitoring
- Overvoltage Protection: DC Type II / AC Type II
- PID Recovery Function (Optional)
Compatible Products
- XW Pro: XW Pro 8548 230 VAC (865-8548-55)
-
Insight Energy Management:
- InsightHome (865-0330)
- InsightFacility (865-0335)
Additional Information
- Country of Manufacture: China
-
Part Numbers:
- CL 30: PVSCL30E
- CL 33: PVSCL33E
- CL 50: PVSCL50E