Fronius Primo Inverters (3.0 to 8.2 kW) Manual


От Erik Zaikin
9 мин чтения


Fronius Primo Inverters (3.0 to 8.2 kW)


Overview

The Fronius Primo inverters, available in power categories from 3.0 to 8.2 kW, are designed for private households. These single-phase, transformerless inverters feature an innovative SuperFlex Design for maximum system design flexibility and an easy-to-install SnapINverter mounting system. The inverters come with a standard communication package including WLAN, energy management, and multiple interfaces, making them highly communicative and efficient for energy management.


Technical Data


Input Data

Model Number of MPP Trackers Max. Input Current (Idc max 1 / Idc max 2) Max. Array Short Circuit Current (MPP1/MPP2) DC Input Voltage Range (Udc min - Udc max) Feed-in Start Voltage (Udc start) Usable MPP Voltage Range Number of DC Connections Max. PV Generator Output (Pdc max)
PRIMO 3.0-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 4.5 kWpeak
PRIMO 3.5-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 5.3 kWpeak
PRIMO 3.6-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 5.5 kWpeak
PRIMO 4.0-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 6.0 kWpeak
PRIMO 4.6-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 6.9 kWpeak
PRIMO 5.0-1 2 12.0 A / 12.0 A 18.0 A / 18.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 7.5 kWpeak
PRIMO 5.0-1 AUS 2 18.0 A / 18.0 A 27.0 A / 27.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 7.5 kWpeak
PRIMO 6.0-1 2 18.0 A / 18.0 A 27.0 A / 27.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 9.0 kWpeak
PRIMO 8.2-1 2 18.0 A / 18.0 A 27.0 A / 27.0 A 80 - 1000 V 80 V 80 - 800 V 2 + 2 12.3 kWpeak

Output Data

Model AC Nominal Output (Pac,r) Max. Output Power / Rated Apparent Power AC Output Current (Iac nom) Grid Connection (Voltage Range) Frequency (Frequency Range) Total Harmonic Distortion Power Factor (cos φac,r)
PRIMO 3.0-1 3,000 W 3,000 VA 13.0 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 3.5-1 3,500 W 3,500 VA 15.2 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 3.6-1 3,680 W 3,680 VA 16.0 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 4.0-1 4,000 W 4,000 VA 17.4 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 4.6-1 4,600 W 4,600 VA 20.0 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 5.0-1 5,000 W 5,000 VA 21.7 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 5.0-1 AUS 4,600 W 5,000 VA / 4,600 VA 21.7 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 6.0-1 6,000 W 6,000 VA 26.1 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.
PRIMO 8.2-1 8,200 W 8,200 VA 35.7 A 1 ~ NPE 220 V / 230 V (180 V - 270 V) 50 Hz / 60 Hz (45 - 65 Hz) < 5 % 0.85 - 1 ind. / cap.

General Data

Model Dimensions (HxWxD) Weight Degree of Protection Protection Class Overvoltage Category (DC / AC) Night Time Consumption Inverter Design Cooling Installation Ambient Temperature Range Permitted Humidity Max. Altitude DC Connection Technology AC Connection Technology Certificates and Compliance Country of Manufacture
PRIMO 3.0-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 3.5-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 3.6-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 4.0-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 4.6-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 5.0-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 5.0-1 AUS 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 6.0-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria
PRIMO 8.2-1 645 x 431 x 204 mm 21.5 kg IP 65 1 2 / 3 < 1 W Transformerless Regulated air cooling Indoor and outdoor installation -40 - +55 °C 0 - 100 % 4,000 m 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² 3-pole AC screw terminals 2.5 - 16 mm² Various (refer to specific standards) Austria

Efficiency

Model Max. Efficiency European Efficiency (ηEU) MPP Adaptation Efficiency
PRIMO 3.0-1 98.0 % 96.1 % > 99.9 %
PRIMO 3.5-1 98.0 % 96.8 % > 99.9 %
PRIMO 3.6-1 98.0 % 96.8 % > 99.9 %
PRIMO 4.0-1 98.1 % 97.0 % > 99.9 %
PRIMO 4.6-1 98.1 % 97.0 % > 99.9 %
PRIMO 5.0-1 98.1 % 97.1 % > 99.9 %
PRIMO 5.0-1 AUS 98.1 % 97.1 % > 99.9 %
PRIMO 6.0-1 98.1 % 97.3 % > 99.9 %
PRIMO 8.2-1 98.1 % 97.5 % > 99.9 %

Protective Devices

Model DC Insulation Measurement Overload Behaviour DC Disconnector Reverse Polarity Protection RCMU
PRIMO 3.0-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 3.5-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 3.6-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 4.0-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 4.6-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 5.0-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 5.0-1 AUS Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 6.0-1 Yes Operating point shift. Power limitation Yes Yes Yes
PRIMO 8.2-1 Yes Operating point shift. Power limitation Yes Yes Yes

Interfaces

Model WLAN / Ethernet LAN 6 Inputs and 4 Digital In/Out USB (A socket) 2x RS422 (RJ45 socket) Signalling Output Datalogger and Webserver External Input RS485
PRIMO 3.0-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 3.5-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 3.6-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 4.0-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 4.6-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 5.0-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 5.0-1 AUS Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 6.0-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection
PRIMO 8.2-1 Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) Interface to ripple control receiver Datalogging, inverter update via USB flash drive Fronius Solar Net Energy management (potential-free relay output) Included S0-Meter Interface / Input for overvoltage protection Modbus RTU SunSpec or meter connection

Additional Information

  • Dynamic Peak Manager: Integrated feature for maximum energy yield.
  • Smart Grid Ready: Ensures future-proof operation with various grid requirements.
  • SnapINverter Technology: Simplifies installation and maintenance.
  • SuperFlex Design: Offers maximum flexibility in system design.
  • Zero feed-in: Feature available to control the amount of energy fed back to the grid.