INGECON SUN STORAGE 3Play 100TL Series Manual


От Erik Zaikin
2 мин чтения


INGECON® SUN STORAGE 3Play TL Series

Overview

The INGECON® SUN STORAGE 100TL is a three-phase, transformerless battery inverter designed for commercial, industrial, and large-scale systems. It offers high power density and advanced features to optimize energy storage and management.

Key Features

  • EMS Inside: Integrated energy management system for advanced functionalities like self-consumption.
  • High Efficiency: Maximum efficiency of 98.8%.
  • Wireless Communication: Ethernet and Wi-Fi included as standard for easy commissioning and monitoring.
  • Robust Design: Aluminium casing suitable for outdoor installations (IP65).
  • Flexibility: Wide input voltage range (570-850 V) and high maximum DC voltage (1,100 V).
  • Compact and Lightweight: 100 kW power with only 80 kg weight.
  • Standard 5 Year Warranty: Extendable upon request.

Main Features

  • EMS inside.
  • Low voltage ride-through capability.
  • Reactive power capability.
  • Compatible with external Cloud Connect software.
  • Integrated Webserver.
  • Software INGECON® SUN Monitor for PV plant monitoring.
  • Suitable for indoor and outdoor installations (IP65).
  • High temperature performance.
  • 4 digital inputs and 2 digital outputs.
  • Pre-charge system required.

Protections

  • Short circuits and overloads at the output.
  • Anti-islanding with automatic disconnection.
  • Insulation faults.
  • AC and DC overvoltages with type 2 surge arresters.

Optional Accessories

  • Self-consumption kit.
  • RS-485 communication.

Benefits

  • Greater power density.
  • Reduced operational costs with wireless communication.
  • High availability compared to central inverters.
  • Easy maintenance.

Technical Specifications

Input (DC)
  • Voltage Range: 627 - 850 V
  • Maximum Voltage: 1,100 V
  • Maximum Power (Charge/Discharge): 60 kW / 100 kW
  • Maximum Current (Charge/Discharge): 96 A / 159 A
  • Battery Type: Li-ion, lead
  • Short Circuit Current: 240 A
  • Communication with BMS: CAN Bus 2.0
Output (AC)
  • Maximum Power (Charge/Discharge): 60 kW / 100 kW
  • Max. Temperature at Rated Power: 50 ºC
  • Maximum Current (Charge/Discharge): 87 A / 145 A
  • Rated Voltage: 400 V
  • Rated Frequency: 50 / 60 Hz
  • Power Factor: 1 (adjustable 0 - 1 leading/lagging)
  • THD: <3%
Efficiency
  • Maximum Efficiency: 98.8%
  • Euroefficiency: 98.1%
General Information
  • Cooling System: Forced ventilation
  • Air Flow: 570 m³/h
  • Stand-by Consumption: 20 W
  • Consumption at Night: 1 W
  • Ambient Temperature: -25 ºC to 60 ºC
  • Relative Humidity: 0 - 100% (non-condensing)
  • Protection Class: IP65 / NEMA 4
  • RCD: 1,000 mA
  • Maximum Operating Altitude: 3,000 m (temperature derates above 1,000 m)
  • Connection:
    • AC: Max. Cross section: 240 mm² (one wire)
    • DC: Max. Cross section: 300 mm² (one wire)
    • Copper and Aluminium cabling permitted for DC and AC
  • Marking: CE
  • EMC and Safety Standards: EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, EN 50178, IEC 62116, IEC 61683, EN 50530, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-68
  • Grid Connection Standards: IEC 61727, EN 50549-1, EN 50549-2, UNE 206007-1 IN, NTS 2.1 SEPE, NTS 1.1 SENP, CEI 0-21, CEI 0-16, Arrete 9 du Juin, ABNT NBR 16149, ABNT NBR 16150, NDU-015, Portaria 73

Dimensions and Weight

  • Dimensions: 720 x 905 x 315 mm
  • Weight: 80 kg

Efficiency Graph

  • Efficiency increases with power, reaching a maximum efficiency of 98.8%.