Ingeteam 1Play TL U M Manual


От Erik Zaikin
4 мин чтения


INGECON® SUN 1Play TL U M Series

Overview

The INGECON® SUN 1Play TL U M series is designed for residential, decentralized commercial, and utility-scale PV systems. These single-phase inverters feature a double MPPT system and are available in four models with power ratings ranging from 2.8 kW to 6 kW. They offer high efficiency, ease of installation and maintenance, and are equipped with advanced safety features such as arc fault circuit interruption (AFCI) and compatibility with 30 mA RCDs.

Key Features

  • High Efficiency: Up to 98.9% efficiency with advanced double MPPT algorithm.
  • Easy Installation: Country-specific configurations and languages selectable via the inverter screen.
  • Simple Operation and Maintenance: User-friendly LCD screen, internal datalogger, remote access, and LED status indicators.
  • Firmware Updating: Easy user-performed firmware updates via SD memory card.
  • Warranty: Standard 10-year warranty, extendable up to 20 years.
  • Certifications: UL 1741 certified.

Main Features

  • AFCI (Arc Fault Circuit Interrupt)
  • Compatible with 30 mA RCDs
  • Double-MPPT system
  • Available from 2.8 kW to 6 kW
  • Up to 98.9% maximum efficiency
  • SiC Technology for higher efficiency and reliability
  • Plug & Play technology
  • USB communications
  • Two digital inputs as standard
  • Software for PV plant access and data registration
  • Suitable for indoor and outdoor installations (NEMA 4)
  • Display-configurable potential-free contact for insulation fault or grid connection indication

Optional Accessories

  • RS-485, Ethernet, Bluetooth, or GSM/GPRS communications
  • Combiner Box with arc-fault circuit interruption and DC switch
  • WeatherBox for meteorological values measurement and registration
  • Four additional digital inputs
  • Self-consumption kit

Protections

  • Reverse polarity
  • Input and output overvoltages (type 3 surge arresters)
  • Output short circuits and overloads
  • Anti-islanding with automatic disconnection
  • Insulation failures

Technical Specifications

Specification 2.8TL U M 3.3TL U M 5TL U M 6TL U M
Input (DC)
Recommended PV array power range (1) 2.8 - 3.6 kW 3.4 - 4.3 kW 5.1 - 6.5 kW 6.1 - 7.8 kW
Voltage range MPP (2) 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V
Voltage range MPP2 (2)(3) 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V
Min. voltage for Pnom with parallel inputs 127 V 150 V 227 V 273 V
Maximum voltage (4) 850 V 850 V 850 V 850 V
Maximum current (Input 1 / Input 2) 11 / 11 A 11 / 11 A 11 / 11 A 11 / 11 A
Inputs (Input 1 / Input 2) 1 / 1 1 / 1 1 / 1 1 / 1
MPPT 2 2 2 2
Output (AC)
Rated power 2.8 kW 3.3 kW 5 kW 6 kW
Max. temperature at rated power (5) 113 ºF 113 ºF 113 ºF 113 ºF
Maximum current 16 A 16 A 26.2 A 26.2 A
Rated voltage 208 / 240 V 208 / 240 V 208 / 240 V 240 V
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Phi Cosine 1 1 1 1
Phi Cosine adjustable Yes. Smax=2.8 kVA Yes. Smax=3.3 kVA Yes. Smax=5 kVA Yes. Smax=6 kVA
THD <3% <3% <3% <3%
Efficiency
Maximum efficiency 98.6% 98.5% 98.4% 98.9%
CEC - Weighted efficiency 97% 97.5% 97.5% 98%
General Information
Refrigeration system Natural air convection Natural air convection Forced ventilation Forced ventilation
Stand-by consumption (6) <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W
Ambient temperature -13 ºF to 149 ºF -13 ºF to 149 ºF -13 ºF to 149 ºF -13 ºF to 149 ºF
Relative humidity (non-condensing) 0 - 100% 0 - 100% 0 - 100% 0 - 100%
Protection class NEMA 4 NEMA 4 NEMA 4 NEMA 4
DC AFCI Yes Yes Yes Yes
Marking CE, ETL CE, ETL CE, ETL CE, ETL
EMC & Security standards UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2 UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2 UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2 UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2
Grid connection standards IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE

Dimensions and Weight

  • 2.8TL U M / 3.3TL U M:

    • Dimensions: 14.17” x 7.09” x 18.5”
    • Weight: 44.1 pounds
  • 5TL U M / 6TL U M:

    • Dimensions: 14.17” x 7.09” x 18.5”
    • Weight: 46.3 pounds

Combiner Box (Optional)

  • DC switch
  • 2 MPPTs (2 inputs per MPPT)
  • Fuses not required, according to NEC 2014 690.9
  • Dimensions: 4.7" x 6.35" x 10.4"
  • Weight: 4 lbs

Notes

  1. Depending on the type of installation and geographical location.
  2. The output power will be conditioned by the voltage and current configuration selected at each input.
  3. To drop to 90 V, the other input must be at least at 125 V.
  4. Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low temperatures.
  5. The output power will be reduced at the rate of 1% for each 1 ºF of increase.
  6. Consumption from PV field.

For further information: