(CTRL + F) hızlı arama için.

AEG AS-IC01-2 (4KW-10KW) Manual

AEG AS-IC01-2 Series Grid-Tied Three-Phase Inverter Overview


General Description

The AEG AS-IC01-2 series inverters are designed for residential PV systems, offering compact design and high efficiency for small and medium-size installations. These inverters provide easy operability and comprehensive monitoring options, making them an ideal choice for various solar installations.


Key Features

  • Compact Design: Ideal for medium-size installations with flexible planning.
  • Efficiency: High efficiency ratings, ensuring optimal energy conversion.
  • Monitoring and Management: Integrated global monitoring system compatible with portable devices.
  • Ease of Installation: Features like built-in DC switch for safe and easy installation.
  • Warranty: Standard 5-year product warranty, with optional extensions to 10, 15, or 20 years.

Technical Specifications

Input (DC)

Model AS-IC01-4000-2 AS-IC01-5000-2 AS-IC01-6000-2 AS-IC01-8000-2 AS-IC01-10000-2
Nominal DC Input Power (W) 4000 5000 6000 8000 10000
Max. DC Input Power (W) 4200 5200 6300 8400 10400
Max. DC Input Voltage (V) 900 900 900 1000 1000
Starting Voltage (V) 200 200 200 300 300
MPPT Operating Voltage Range (V) 200-800 200-800 200-800 200-800 200-800
Operation Voltage (V) 210-800 260-800 310-800 350-800 400-800
Number of MPPT / String per MPPT 2/1 2/1 2/1 2/1 2/1
Max. DC Current (A) per MPPT x Nr. of MPPT 10 x 2 10 x 2 10 x 2 12 x 2 12.5 x 2
Isc PV (A) 11 x 2 11 x 2 11 x 2 13 x 2 14 x 2
Maximum Backflow Current (A) 0 0 0 0 0
DC Switch Integrated Integrated Integrated Integrated Integrated

Output (AC)

Model AS-IC01-4000-2 AS-IC01-5000-2 AS-IC01-6000-2 AS-IC01-8000-2 AS-IC01-10000-2
Rated Output Power (W) 4000 5000 6000 8000 10000
Max. Apparent Power SEmax (VA) 4002 5018 6017 8038 9789
Max. AC Output Current (A) 6.4 8.0 9.6 12.5 14
Maximum Output Overcurrent Protection (A) 12.7 15.8 19 24.7 27.7
Maximum Output Fault Current (A) 265A @ 34ms 265A @ 34ms 265A @ 34ms 265A @ 34ms 265A @ 34ms
AC Inrush Current <10A <10A <10A <10A <10A
Voltage (V) / Frequency (Hz) 230400 Vac, 50 Hz (4751.5 Hz) 230400 Vac, 50 Hz (4751.5 Hz) 230400 Vac, 50 Hz (4751.5 Hz) 230400 Vac, 50 Hz (4751.5 Hz) 230400 Vac, 50 Hz (4751.5 Hz)
Power Factor -0.9 ~ +0.9 (adjustable) -0.9 ~ +0.9 (adjustable) -0.9 ~ +0.9 (adjustable) -0.9 ~ +0.9 (adjustable) -0.9 ~ +0.9 (adjustable)
THDi <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power) <3% (at rated power)
AC Output Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE) Three-phase (L1, L2, L3, N, PE) / (L1, L2, L3, PE)

Mechanical Parameters

Model AS-IC01-4000-2 to AS-IC01-6000-2 AS-IC01-8000-2 to AS-IC01-10000-2
Dimensions (H x W x D, mm) 530 x 360 x 150 575 x 360 x 150
Weight (kg) 20 23
DC Terminal BC03A, BC03B BC03A, BC03B
Installation Wall-mounting Wall-mounting
Safety Certificates / EMC Category / Grid Standards IEC 62109-1 (ed.1), IEC 62109-2 (ed.1), EN 62109-1:2010, EN 62109-2:2011, EN 61000-6-3:2007+A1:2011, EN 61000-6-2:2005; VDE-AR-N 4105:2018, DIN VDE V 0124-100:20, EN 50549-1:2019, C10/11:2019 IEC 62109-1 (ed.1), IEC 62109-2 (ed.1), EN 62109-1:2010, EN 62109-2:2011, EN 61000-6-3:2007+A1:2011, EN 61000-6-2:2005; VDE-AR-N 4105:2018, DIN VDE V 0124-100:20, EN 50549-1:2019, C10/11:2019
Noise (dB) ≤30 <50

System

| Cooling | Natural cooling | Air cooling | | Max. Efficiency (%) | 97.20 - 98.20 | | Euro-Efficiency (%) | 97.00 - 97.60 | | MPPT Efficiency (%) | 99.90 | | Protection Rating | IP65 | | Power Consumption at Night (W) | <1 | | Topology and Isolation Mode | Non-isolated, transformerless | | Operating Temperature | -25°C ~ +60°C (derate after 45°C) | | Relative Humidity | 4 ~100%, condensation | | Max. Altitude (m) | ≤2000 (derate if the altitude >2000) | | Overvoltage Protection Class and Safety Class | AC

, PV
; Safety Class I | | Protection | Input overvoltage protection, input overcurrent protection, DC isolation monitoring, DC monitoring, grounding fault current monitoring, grid monitoring, island protection, short circuit protection, overheating protection |

 

Display and Communication

| Display | LCD | | System Language | English, German, Dutch | | Communication | RS485 + WiFi (Standard), Ethernet (Optional) |

Warranty

| Product Warranty | 5 years (optional: 10/15/20 years) |

Bloga dön