(CTRL + F) hızlı arama için.

FIMER PVI-55.0/330.0 Series Manual

Overview of Solar Inverters: FIMER PVI-55.0/330.0 Series

Key Features

  • Power Range: From 55 kW to 300 kW using modular 55 kW blocks.
  • Efficiency: Up to 98% efficiency (for TL versions).
  • MPPT Channels: High-speed Maximum Power Point Tracking for optimized energy harvesting.
  • Input Voltage: Maximum DC input voltage of up to 1000 Vdc.
  • Flexibility: Suitable for large scale PV plants with reduced DC distribution losses.
  • Pre-configured Systems: Delivered pre-configured and pre-tested, reducing on-site wiring and testing.
  • Modularity: Each module operates independently, so a failure in one module does not affect others.

Technical Specifications

Inverter Models

  • PVI-55.0/110.0
  • PVI-165.0/220.0
  • PVI-275.0/330.0

Input Side

  • DC Voltage Range: 485...950 V
  • MPPT Range: 485...800 V
  • Input Current: Up to 738 A combined, 123 A per module.
  • DC Inputs: Multiple pairs depending on the model.
  • Protection: Reverse polarity protection, input overvoltage protection, and residual current protection.

Output Side

  • AC Grid Connection: Three phases, with 4W+PE or 3W+PE options.
  • Rated Power: Varies from 55 kW to 330 kW.
  • Voltage Range: 320...480 V
  • Output Current: Up to 606 A
  • Frequency Range: 47...63 Hz
  • Power Factor: > 0.995 (adjustable ±0.90)
  • Total Harmonic Distortion: < 3%

Environmental and Physical

  • Temperature Range: -10...+60°C with derating above 50°C.
  • Humidity: 0...95% non-condensing.
  • Noise Emission: <72 dB(A) @ 1m, varying by model.
  • Protection Rating: IP 20
  • Cooling: Air forced, with required cooling flow varying by model.
  • Dimensions: Varies from 1077mm x 1250mm x 850mm to 2184mm x 1250mm x 850mm.
  • Weight: From <350 kg to <1300 kg, depending on the model.

Safety and Standards

  • Transformer: Available in models with and without transformers.
  • Marking: CE (50 Hz only)
  • Safety and EMC Standards: EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12.
  • Grid Standards: CEI 0-21, CEI 0-16, BDEW, RD 661/2007, RD 1565/2010, P.O.12.3 (check for availability by region).

Communication and Monitoring

  • Local Monitoring: PVI-USB-RS232_485 (optional)
  • Remote Monitoring: PVI-AEC-EVO (optional), VSN700 Data Logger (optional)
  • String Combiner: PVI-STRINGCOMB (optional)
  • User Interface: 16 characters x 2 line LCD display for each module

Highlights

  • Fault Susceptibility: Reduced susceptibility to single faults with a maximum of 55 kW lost per module.
  • Noise Reduction: Reduced acoustic noise due to high switching frequency.
  • Integrated Protection: DC and AC distribution and protection integrated.
  • Monitoring: Two independent RS-485 communication interfaces for smart monitoring.
  • DC Disconnect Switch: Integrated for each 55 kW module, with replaceable fuses and overvoltage protection.
  • Revamping Applications: Ideal for MV connected PV systems revamping without changing the MV transformer.
  • TL Versions: Available with different AC voltage standards (e.g., CEI 0-16).
  • Wider MPPT Range: Enhanced MPPT range for better energy harvesting.

Conclusion

The FIMER PVI-55.0/330.0 series of solar inverters offers a highly efficient, modular solution for various PV plant configurations, providing robust performance and easy integration for large-scale solar energy systems. The modularity and independent operation of each 55 kW block ensure that the overall system performance remains high even if individual modules are affected, making it a reliable choice for both new installations and revamping existing systems.

Bloga dön

İletişim formu