KACO Blueplanet 155 + 165 TL3 Inverters Manual
Share
KACO Blueplanet 155 + 165 TL3 Inverters
Overview
The KACO Blueplanet 155 and 165 TL3 string inverters are tailored for utility-scale solar power plants, including multi-megawatt solar parks. These inverters boast superior efficiencies and overload capacities due to silicon carbide technology, facilitating easy logistics and installation. They also support both decentralized designs and the "Virtual Central" concept, with robust overvoltage protection for AC, DC, and communication interfaces.
Key Features
- Superior Efficiency: Enhanced efficiencies and overload capacity with silicon carbide technology.
- High Power Density: Facilitates easy logistics and installation.
- Flexible Design: Supports decentralized and "Virtual Central" system concepts.
- Overvoltage Protection: AC/DC and communication interface protection available.
- Remote Management: Lean commissioning and updates via remote services.
Technical Specifications
DC Input Data
Specification | 155 TL3 | 165 TL3 |
---|---|---|
Max. recommended PV generator power | 232,500 W | 247,500 W |
MPP range | 875 – 1,300 V | 960 – 1,300 V |
Operating range | 875 – 1,450 V | 960 – 1,450 V |
Rated DC voltage / start voltage | 900 V / 1,000 V | 1,000 V / 1,100 V |
Max. no-load voltage | 1,500 V | 1,500 V |
Max. input current | 183 A | 183 A |
Max. short circuit current Isc max | 300 A | 300 A |
Number of MPP trackers | 1 | 1 |
Connection per tracker | 1 – 2 | 1 – 2 |
AC Output Data
Specification | 155 TL3 | 165 TL3 |
---|---|---|
Rated output | 155,000 VA | 165,000 VA |
Max. power | 155,000 VA | 165,000 VA |
Line voltage | 600 V (3P+PE) | 660 V (3P+PE) |
Voltage range (Ph-Ph) | 480 – 690 V | 480 – 760 V |
Rated frequency (range) | 50 Hz / 60 Hz (45 – 65 Hz) | 50 Hz / 60 Hz (45 – 65 Hz) |
Rated current | 3 x 149.5 A | 3 x 144.5 A |
Max. current | 3 x 152.0 A | 3 x 152.0 A |
Reactive power / cos phi | 0 – 100% Snom / 0.30 ind. – 0.30 cap. | 0 – 100% Snom / 0.30 ind. – 0.30 cap. |
Max. total harmonic distortion (THD) | ≤ 3% | ≤ 3% |
Number of grid phases | 3 | 3 |
General Data
Specification | 155 TL3 | 165 TL3 |
---|---|---|
Max. efficiency | 99.1% | 99.1% |
European efficiency | 98.9% | 99.0% |
CEC efficiency | 98.9% | 99.0% |
Standby consumption | < 10 W | < 10 W |
Circuitry topology | Transformerless | Transformerless |
Mechanical Data
Specification | 155 TL3 | 165 TL3 |
---|---|---|
Display | LEDs | LEDs |
Control units | Webserver, supports mobile devices | Webserver, supports mobile devices |
Interfaces | Ethernet (Modbus TCP, Sunspec), RS485 (KACO-protocol), USB, optional: 4-DI | Ethernet (Modbus TCP, Sunspec), RS485 (KACO-protocol), USB, optional: 4-DI |
Fault signalling relay | Potential-free NOC max. 30 V / 1 A | Potential-free NOC max. 30 V / 1 A |
DC connection | Cable lug, max. 240 mm² (0.372 in²) Cu or Al | Cable lug, max. 240 mm² (0.372 in²) Cu or Al |
AC connection | Cable lug, max. 240 mm² (0.372 in²) Cu or Al | Cable lug, max. 240 mm² (0.372 in²) Cu or Al |
Ambient temperature | -25 °C – +60 °C 1) | -25 °C – +60 °C 1) |
Humidity | 0 – 100% | 0 – 100% |
Max. installation elevation (above MSL) | 3,000 m | 3,000 m |
Min. distance from coast | 500 m | 500 m |
Cooling | Temperature controlled fan | Temperature controlled fan |
Protection class | IP66 / NEMA 4X | IP66 / NEMA 4X |
Noise emission | 59.2 dB (A) | 59.2 dB (A) |
Dimensions (H x W x D) | 719 x 699 x 460 mm | 719 x 699 x 460 mm |
Weight | 78.2 kg | 78.2 kg |
Certifications
- Safety: IEC 62109-1/-2, EN 61000-6-1/-2/-4, EN 61000-3-11/-12, EN 55011 group 1, class A, EN 62920 Emission class A / Immunity class A, UL62109-1, UL1741, CSA-C22.2 No.107.1, CSA-C22.2 No.62109-1, CSA-C22.2 No.62109-2
- Grid Connection Rule Overview: Available on the homepage/download area
Versions
Feature | S | XL |
---|---|---|
Number of DC inputs | 1 – 2 | 1 – 2 |
DC switch | - | ✔ |
DC SPD | Type 1 + 2 | Type 1 + 2 |
AC SPD | ⦻ | ⦻ |
RS485 interface SPD | ⦻ | ⦻ |
Ethernet interface SPD | ⦻ | ⦻ |
PID Set | ⦻ | ⦻ |
- ✔ = Standard
- ⦻ = Upgradeable