Omron KP100L Manual
Share
General Description
- Model: KP100L Photovoltaic Inverter
-
Features:
- Versatile matching for Monocrystal and Polycristal solar modules
- Top level performance with 3 MPPT and wide MPPT voltage range
- Max peak output power (+10%)
- Smart control for solar tracker
- Applicable Countries: Italy, Spain, France, Germany, Czech Republic, Portugal, Greece (Mainland), Denmark, Turkey, Republic of South Africa
- Order Code: KP100L-OD-EU
Specifications
DC Input
- Max. open-circuit voltage: 850 VDC
- DC voltage range: 200 to 850 VDC
- MPPT voltage range: 225 to 850 VDC
- Nominal voltage: 585 VDC
- Number of MPPT: 3
- Type of DC terminals: MC4
- Max. current per one pair of DC terminals: 13 ADC
- Max. power per one pair of DC terminals: 5,500 W
AC Output
- Nominal power: 10,000 W
- Peak power (10 minutes): 11,000 W
- Nominal Output Current: 14.5 A
- Output voltage: 230/400 VAC
- Nominal frequency: 50 Hz
- Output frequency range: 45 to 55 Hz
- THD of output current: 4% or less
- Power factor (cos phi): 1 (typical) (at output power 10 kW)
- Wiring system: 3-phase 4-wire
Performance
- Max. efficiency: 97.5%
- European efficiency: 97.1%
- Standby consumption power: 1 W or less
- Night time consumption power: 1 W or less
Certifications
- EMC: EN 61000-6-2, EN 61000-6-3, EN 61000-3-2
- Low voltage regulation: EN50178
- German regulation: VDE0126-1-1
- Spanish regulation: RD1663/2000
- Italian regulation: DK5940 Ed2.2
Other Specifications
- Operation temperature range: 20 to +60C
- Tolerable relative humidity: 4 to 100%, non-condensing
- Degree of protection: Housing: IP65 (acc. To DIN EN60529)
- Cooling: Forced ventilation
- Dimensions (W H D): 455 700 270 mm
- Weight: Approx. 42 kg
- Display: LCD (16 characters, 2 lines)
- Data transmission: RS-232C/RS-485
- Warranty: 5 years (Option for 10 years)
Key Features
- ZCC Circuit: Developed in collaboration with a leading Japanese university, enhancing efficiency and power output.
- 3 Individual MPP Trackers: Ensures high power efficiency and maximum power output.
Diagram Description
- The inverter contains:
- EMI Filters
- 3 Boosters with MPPT
- DC/AC converter
- AC breaker
- Ground fault breaker (RCD)
- SPD (Surge Protection Device)
- DC switch or breaker
- DC Bus RLY1 and RLY2
- CPU1 and CPU2 for control
- Communication facilities (RS-232C or RS-485)
- AUX facilities (AUX_IN, AUX_OUT)
- The internal structure highlights the use of ZCC circuits and individual MPPTs.
Interface
- Data Transmission: RS-232C/RS-485