(CTRL + F) hızlı arama için.

Omron KP100L Manual

General Description

  • Model: KP100L Photovoltaic Inverter
  • Features:
    • Versatile matching for Monocrystal and Polycristal solar modules
    • Top level performance with 3 MPPT and wide MPPT voltage range
    • Max peak output power (+10%)
    • Smart control for solar tracker
  • Applicable Countries: Italy, Spain, France, Germany, Czech Republic, Portugal, Greece (Mainland), Denmark, Turkey, Republic of South Africa
  • Order Code: KP100L-OD-EU

Specifications

DC Input

  • Max. open-circuit voltage: 850 VDC
  • DC voltage range: 200 to 850 VDC
  • MPPT voltage range: 225 to 850 VDC
  • Nominal voltage: 585 VDC
  • Number of MPPT: 3
  • Type of DC terminals: MC4
  • Max. current per one pair of DC terminals: 13 ADC
  • Max. power per one pair of DC terminals: 5,500 W

AC Output

  • Nominal power: 10,000 W
  • Peak power (10 minutes): 11,000 W
  • Nominal Output Current: 14.5 A
  • Output voltage: 230/400 VAC
  • Nominal frequency: 50 Hz
  • Output frequency range: 45 to 55 Hz
  • THD of output current: 4% or less
  • Power factor (cos phi): 1 (typical) (at output power 10 kW)
  • Wiring system: 3-phase 4-wire

Performance

  • Max. efficiency: 97.5%
  • European efficiency: 97.1%
  • Standby consumption power: 1 W or less
  • Night time consumption power: 1 W or less

Certifications

  • EMC: EN 61000-6-2, EN 61000-6-3, EN 61000-3-2
  • Low voltage regulation: EN50178
  • German regulation: VDE0126-1-1
  • Spanish regulation: RD1663/2000
  • Italian regulation: DK5940 Ed2.2

Other Specifications

  • Operation temperature range: 20 to +60C
  • Tolerable relative humidity: 4 to 100%, non-condensing
  • Degree of protection: Housing: IP65 (acc. To DIN EN60529)
  • Cooling: Forced ventilation
  • Dimensions (W  H  D): 455  700  270 mm
  • Weight: Approx. 42 kg
  • Display: LCD (16 characters, 2 lines)
  • Data transmission: RS-232C/RS-485
  • Warranty: 5 years (Option for 10 years)

Key Features

  • ZCC Circuit: Developed in collaboration with a leading Japanese university, enhancing efficiency and power output.
  • 3 Individual MPP Trackers: Ensures high power efficiency and maximum power output.

Diagram Description

  • The inverter contains:
    • EMI Filters
    • 3 Boosters with MPPT
    • DC/AC converter
    • AC breaker
    • Ground fault breaker (RCD)
    • SPD (Surge Protection Device)
    • DC switch or breaker
    • DC Bus RLY1 and RLY2
    • CPU1 and CPU2 for control
    • Communication facilities (RS-232C or RS-485)
    • AUX facilities (AUX_IN, AUX_OUT)
  • The internal structure highlights the use of ZCC circuits and individual MPPTs.

Interface

  • Data Transmission: RS-232C/RS-485
Bloga dön

İletişim formu