PowerTRIO Manual
Share
PowerTRIO - Hybrid String Inverter
Models: FIM-HY-4.0/5.0/6.0/7.5/8.5-SE-A-3PH
Key Benefits
- Better 3-phase PowerTRIO
- Better Flexibility: Battery-ready inverter, DC or AC coupled, full power 100% unbalanced backup
- Better Installability: Plug & play connections, integrated spirit level
- Better Security: Patented AFCI, PLC Rapid Shutdown compatibility
- Better Connectivity: Embedded Wi-Fi, ethernet and USB, blockchain ready
Features
- USB port, ethernet port, smart plug, and coin cell
- Wi-Fi/AFCI button
- Battery communication
- AC backup
- Wi-Fi antenna
- AC grid
- Hypercap
- MC4 battery power connector
- MPPT 1 and MPPT 2 with MC4 inputs
- DC switch as standard
- Available power: 4 kW to 8.5 kW
- Real-time monitoring 24/7
- No tools required for commissioning
- ARC fault detection (Patented)
- SG ready & EV charger
- Built-in unbalanced load backup
- Blockchain ready
- CPU performance +55%
- Switching frequency x2 faster
- Time saving for commissioning +40%
- Noise reduction -20 dB (A)
Technical Data and Types
Input Side
- Absolute maximum DC input voltage (Vmax,abs): 850 V for 4.0, 5.0, 6.0; 1000 V for 7.5, 8.5
-
Start-up DC input voltage (Vstart):
- 200 V (adj. 150…500 V) for 4.0
- 200 V (adj. 180…500 V) for 5.0
- 200 V (adj. 200…500 V) for 6.0
- 215 V (adj. 215…500 V) for 7.5, 8.5
-
Operating DC input voltage range (Vdcmin...Vdcmax):
- 0.7 x Vstart...750 V (min 105 V) for 4.0
- 0.7 x Vstart…750 V (min 125 V) for 5.0
- 0.7 x Vstart…750 V (min 140 V) for 6.0
- 0.7 x Vstart…850 V (min 150 V) for 7.5, 8.5
- Rated DC input voltage (Vdcr): 625 V
-
Rated DC input power (Pdcr):
- 4082 W for 4.0
- 5102 W for 5.0
- 6122 W for 6.0
- 7143 W for 7.5
- 8673 W for 8.5
- DC/AC ratio: Up to 200%, according to location
- Number of independent MPPT: 2
-
Maximum DC input power for each MPPT (PMPPT max):
- 3061 W, linear derating [750 ≤ VMPPT ≤ 850 V] for 4.0
- 3827 W, linear derating [750 ≤ VMPPT ≤ 850 V] for 5.0
- 4592 W, linear derating [750 ≤ VMPPT 850 V] for 6.0
- 5625 W, linear derating [850 ≤ VMPPT ≤ 975 V] for 7.5
- 6505 W, linear derating [850 ≤ VMPPT ≤ 975 V] for 8.5
-
DC input voltage range with parallel configuration of MPPT at Pacr, not operative battery:
- 150…750 V for 4.0
- 180…750 V for 5.0
- 200…750 V for 6.0
- 270…850 V for 7.5
- 300…850 V for 8.5
-
Maximum DC input current (Idc max) / for each MPPT (IMPPT max): 26 / 13 A
- 32.5/19.5 A - 13 A (MPPT1 - MPPT2)
- Maximum input short circuit current for each MPPT: 24 A
- Number of DC inputs pairs for each MPPT: 1 for 4.0, 2 - 1 (MPPT1 - MPPT2) for others
- DC connection type: PV quick fit connector
Input Protection
- Reverse polarity protection: Yes, from limited current source
- Input over voltage protection for each MPPT - varistor: Yes, TYPE II protection class
- Photovoltaic array isolation control: According to local standard
- DC switch rating for each MPPT: 30A/1000V - 30A/600V (DC-PV2)
Battery Port
-
Operating DC voltage range:
- 625...750 V for 4.0, 5.0, 6.0
- 625...850 V for 7.5, 8.5
- PowerX Max. units: 3
-
Max. charge power:
- 4000 W for 4.0
- 5000 W for 5.0
- 6000 W for 6.0
- 7500 W for 7.5
- 8500 W for 8.5
-
Max. discharge power:
- 4000 W for 4.0
- 5000 W for 5.0
- 6000 W for 6.0
- 7500 W for 7.5
- 8500 W for 8.5
Grid Connected Output Side
- AC Grid connection type: Three-phase (3W+PE or 4W+PE)
-
Rated AC power (Pacr @cosφ=1):
- 4000 W for 4.0
- 5000 W for 5.0
- 6000 W for 6.0
- 7500 W for 7.5
- 8500 W for 8.5
-
Maximum AC output power (Pacmax @cosφ=1):
- 4000 W for 4.0
- 5000 W for 5.0
- 6000 W for 6.0
- 7500 W for 7.5
- 8500 W for 8.5
-
Maximum apparent power (Smax):
- 4000 VA for 4.0
- 5000 VA for 5.0
- 6000 VA for 6.0
- 7500 VA for 7.5
- 8500 VA for 8.5
- Rated AC grid voltage (Vac,r): 380 V / 400 V / 415 V
- AC voltage range: 320...480 V
-
Maximum AC output current (Iac max):
- 6.1 A for 4.0
- 7.6 A for 5.0
- 9.0 A for 6.0
- 10.6 A for 7.5
- 12.9 A for 8.5
-
Contributory fault current:
- 6.1 A for 4.0
- 7.6 A for 5.0
- 9.0 A for 6.0
- 10.6 A for 7.5
- 12.9 A for 8.5
- Rated output frequency (fr): 50 Hz / 60 Hz
- Output frequency range (fmin...fmax): 45...55 Hz / 55…65 Hz
- Nominal power factor and adj. range: > 0.995, adj. ± 0.8 - 1 (over/under excited)
- Total current harmonic distortion: < 3%
- AC connection type: Female panel connector
Grid Connected Output Protection
- Anti-islanding protection: According to local standard
- Maximum external AC overcurrent protection:
- 16A for 4.0, 5.0, 6.0
- 20A for 7.5, 8.5
- Output overvoltage protection - varistor: Yes, TYPE II protection class
Efficiency
- Maximum efficiency: 98.2%
- MPPT efficiency: 98.9%
Backup Output Side
- AC grid connection type: Three-phase
-
Maximum apparent power (Smax):
- 4000 VA for 4.0
- 5000 VA for 5.0
- 6000 VA for 6.0
- 7500 VA for 7.5
- 8500 VA for 8.5
- Rated AC grid voltage (Vacr): 400 V
- AC voltage range: 320...480 V
-
Maximum AC output current (Iac max):
- 5.8 A for 4.0
- 7.2 A for 5.0
- 8.7 A for 6.0
- 10.6 A for 7.5
- 12.9 A for 8.5
- Rated output frequency (fr): 50 Hz / 60 Hz
- Output frequency range (fmin...fmax): 45...55 Hz / 55…65 Hz
- AC connection type: Female panel connector
Backup Output Protection
- Maximum external AC overcurrent protection:
- 10A for 4.0
- 16A for others
- Output overvoltage protection - varistor: Yes, TYPE II protection class
Embedded Communication
- Embedded physical interface: Wi-Fi, ethernet, RS-485
- Embedded communication protocols: Modbus TCP (SunSpec), Modbus RTU (SunSpec)
- Datalogger data retention: 30 days
- Remote monitoring: Energy Viewer (mobile APP), Energy viewer Web, Plant Portfolio Manager
- Local monitoring: Energy Viewer (mobile APP)
Environmental
- Ambient temperature range: -25...+60°C with derating above 50°C
- Relative humidity: 4…100 % condensing
- Acoustic noise emission level: < 30 dB (A) @ 1 m
- Maximum operating altitude without derating: 2000 m / 6560 ft
Physical
- Environmental protection rating: IP65
- Cooling: Natural
- Dimension (H x W x D): 370 mm x 520 mm x 185 mm
- Weight: 18 kg
- Mounting system: Wall bracket
Safety
- Isolation level: Transformerless
- Marking: CE, RCM
- Safety and EMC standard: IEC/EN 62109-1, IEC/EN 62109-2, IEC 62477-1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN61000-3-12
- Grid standards (check your sales channel for availability): CEI 0-21, EN 50549-1, DIN V VDE V 0126-1-1, VDE-AR-N 4105, AS/NZS 4777.2, IEC 61727, IEC 62116
Other Features
- Load manager: Yes, with integrated relays
- AC backup output, off grid: Yes
- Battery charge from AC: Yes, using time of usage policy
- AC-coupled mode: Yes, settable during commissioning